Clinical Trials Directory

Trials / Unknown

UnknownNCT06218186

Assessing the Performance of Wesper Lab for Sleep Apnea Diagnosis in Pediatric Populations

A Single Arm Quantitative Study Assessing Performance of Wesper Lab as a Tool to Aid in Sleep Apnea Diagnosis in Pediatric Populations

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
150 (estimated)
Sponsor
Wesper Inc · Industry
Sex
All
Age
2 Years – 21 Years
Healthy volunteers
Not accepted

Summary

The goal of this single arm study is to evaluate the effectiveness of Wesper Lab, previously known as TatchSleep Pro, a wireless home sleep test, as a tool to aid in sleep apnea diagnosis as compared to an overnight polysomnography (PSG) evaluation in a pediatric population (subjects 2 to 21 years of age). The main question\[s\] it aims to answer are: * Does Wesper Lab demonstrate agreement with PSG for the calculation of the apnea/hypopnea index (AHI)? * Does Wesper Lab demonstrate agreement with PFG for the calculation of sleep apnea severity. Participants that are already undergoing a prescribed PSG for the detection of sleep apnea will be asked to simultaneously wear the Wesper Lab sensors and an FDA approved pulse oximeter. Researchers will compare the AHI of Wesper Lab to the AHI of the PSG to determine the accuracy of the Wesper Lab device. This is a single center, single-arm, quantitative study

Detailed description

This is a single center, single-arm, quantitative study evaluating the effectiveness of the Wesper Lab, previously known as TatchSleep Pro, wireless sensors as a tool to aid in sleep apnea diagnosis as compared to an overnight polysomnography (PSG) evaluation in a pediatric population. Investigators will identify approximately 150 eligible pediatric patients, 50 subjects per subgroup, who have been recommended to receive an overnight PSG for the detection/evaluation of sleep apnea. Subgroups include pediatric patients in the following age ranges: subgroup 1: 2-5 years old, subgroup 2: 6-11 years old, subgroup 3: 12-21 years old. After informed consent is obtained, a brief sleep-related medical history will be collected including relevant demographics. Females of childbearing potential (12 years or older) will be asked to undergo a urine dipstick pregnancy test to determine their eligibility for inclusion in the study. Patients will undergo their PSG test while simultaneously wearing 2 Wesper Lab patches and an FDA-cleared pulse oximeter compatible with and connected to the Wesper Lab system for a single night at the clinic. The same make and model of pulse oximeter will be used for all subjects. Patients will be observed overnight by trained sleep technicians who will setup the Wesper Lab device and collect the sleep data via the companion smartphone application. A follow-up communication will be made with patients within 5 days after the sleep study to assess any adverse events. Following the data collection, sleep data from PSG and Wesper Lab will be scored by an independent qualified sleep technologist (the primary reader) to yield an analysis of the accuracy of Wesper Lab compared with the PSG signals. At least one and up to two additional readers (secondary readers) will score only the Wesper Lab data to obtain an estimate of inter-rater reliability. Accuracy of the Wesper Lab device will be demonstrated by comparing the Pearson correlation of Wesper Lab and PSG AHI to a performance goal. The performance goal is based on a meta-analysis of FDA-cleared similar devices. Fisher's transformation and one-sided Z-test will be used to test the hypotheses with a significance level of 0.025. The upper and lower 95% Bland-Altman limits of agreement will be calculated and statistically compared using a Wald test to performance goals based on a meta-analysis of FDA-cleared similar devices. Deming regression will also be presented. The inter-rater reliability of Wesper Lab AHIs will be calculated.

Conditions

Interventions

TypeNameDescription
DEVICEMedical Device: Wesper Lab Home Sleep TestWesper Lab is a medical device that is used for the diagnosis of sleep apnea. Wesper lab is composed of two flexible biosensors that adhere to the abdomen and thorax with medical grade adhesive. A FDA approved pulse oximeter is worn on a finger.

Timeline

Start date
2024-03-01
Primary completion
2025-03-01
Completion
2025-04-01
First posted
2024-01-23
Last updated
2024-01-23

Locations

1 site across 1 country: United States

Regulatory