Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06200974

Multi-omic Approach to Study HDR Brachytherapy for Favorable Risk and Low Tier Intermediate Risk Prostate Cancer

Multi-omic Approach to Study High Dose Rate (HDR) Brachytherapy for Favorable Risk and Low Tier Intermediate Risk Prostate Cancer

Status
Recruiting
Phase
Study type
Observational
Enrollment
100 (estimated)
Sponsor
British Columbia Cancer Agency · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This is an observational single-center trial for patients with localized prostate cancer suitable for High Dose Rate (HDR) brachytherapy as monotherapy. This study takes a multi-omics approach to study the mechanism of action of HDR brachytherapy through metabolomics, immunological, transcriptomics, and spectroscopic profiling. The results of this study will clarify the optimal dose for HDR prostate brachytherapy by documenting the dose-response relationship seen in the changing tumor metabolites after HDR brachytherapy and investigate the immunogenicity of HDR brachytherapy.

Detailed description

High Dose Rate (HDR) prostate brachytherapy is an effective and highly conformal means of delivering curative radiation to the prostate. Because of the high dose rate, initial studies applied this treatment cautiously in multiple sessions or fractions but this has gradually been reduced from 54 Gy in 9 fractions to 42 Gy in 6, then 36 Gy in 3, then 27 Gy in 2 and finally to one single fraction of 19 Gy. Each change in fractionation was calculated to be equivalent to the previous, and remarkably, efficacy was maintained until the final stage when treatment was reduced to a single fraction. This resulted in a significant drop in cure rates from over 90% to approximately 65%. The investigators assume that the prior fractions served to sensitize the tumor to subsequent radiation; however, this remains an open question. This observational single-center trial for localized prostate cancer suitable for brachytherapy as monotherapy takes a novel multi-omics approach to study the mechanism of action of High Dose Rate (HDR) brachytherapy through metabolomics, immunological, transcriptomics, and spectroscopic profiling. This is achieved through (1) measurement of changes in metabolites as determined by Raman spectroscopy, (2) analysis of circulating tumor DNA in peripheral blood plasma, (3) evaluation of the changes in immune response by single cell RNA (scRNA)-sequencing, and (4) evaluation of gut microbiome composition before and after treatment. Secondary endpoints of the study include PSA nadir, time to nadir, PSA at 4 years and patterns of failure. The study will enroll 100 men with localized prostate cancer suitable for brachytherapy as monotherapy. HDR brachytherapy is given in 2 fractions, each one under anesthesia, making it possible to obtain biopsies painlessly at both baseline prior to any treatment, and 1-2 weeks later prior to the second half of treatment. The results of this study will clarify the dose-response relationship for HDR brachytherapy, help to define the optimal dose, clarify the metabolic response to HDR brachytherapy, and investigate the potential immunogenicity of HDR brachytherapy.

Conditions

Interventions

TypeNameDescription
RADIATIONHigh dose rate prostate brachytherapyTemporary implantation of radioactive material into the prostate in the form of a stepping source of Iridium 192 that travels through 16-18 needles or catheters strategically placed through the prostate.

Timeline

Start date
2024-02-01
Primary completion
2028-03-01
Completion
2038-02-01
First posted
2024-01-11
Last updated
2026-02-02

Locations

1 site across 1 country: Canada

Source: ClinicalTrials.gov record NCT06200974. Inclusion in this directory is not an endorsement.