Trials / Completed
CompletedNCT06187987
Mechanical Thrombectomy With the FlowTriever Device in Acute Pulmonary Embolism - a Retrospective Analysis
Outcomes of Mechanical Thrombectomy With the FlowTriever Device in Acute Pulmonary Embolism, Results of a Swedish Retrospective Analysis
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 132 (actual)
- Sponsor
- Kristina Svennerholm · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
International guidelines recommend intravenous thrombolysis (IVT) for high-risk pulmonary embolism (PE). In high-risk PE where IVT is contraindicated or has failed, surgical embolectomy or catheter-directed intervention (CDI) is recommended. CDI is also recommended as an alternative in patients with intermediate-risk PE with haemodynamic deterioration during anticoagulation treatment. Although there is a lack of randomized studies comparing CDI to anticoagulation or systemic thrombolysis in PE, several studies and recent meta-analyses have shown that CDI is an effective treatment that is associated with fewer complications than IVT, especially bleeding.
Detailed description
The FlowTriever® retrieval/aspiration system is the first mechanical thrombectomy device to receive PE as an indication from the United States Food and Drug administration agency. It combines large-bore aspiration with expanding mesh disks designed to trap and subsequently retract the blood clots from the pulmonary arteries. While Inari Medical, the medical device company that produces the FlowTriever® system, has initiated and published a few prospective trials on FlowTriever® in PE, non-industry sponsored studies are small and mostly retrospective. In 2021 FlowTriever® became the primary device for CDI in PE at Sahlgrenska University Hospital in Gothenburg, Sweden. Concurrently, several hospitals in Sweden have started using FlowTriever® in high-risk PE. As such, the method needs evaluation and validation on a local and national level. This retrospective observational study aims to evaluate the outcomes of patients with acute PE treated with the FlowTriever® device in Sweden. A control group consisting of PE patients treated with IVT will be used for comparison.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Mechanical thrombectomy | Aspirational mechanical thrombectomy |
| DRUG | Intravenous thrombolysis | Intravenous thrombolysis with tissue-type plasminogen activator (tPA) |
Timeline
- Start date
- 2023-04-01
- Primary completion
- 2025-01-31
- Completion
- 2025-03-31
- First posted
- 2024-01-03
- Last updated
- 2025-05-20
Locations
1 site across 1 country: Sweden
Regulatory
- FDA-regulated drug study
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT06187987. Inclusion in this directory is not an endorsement.