Clinical Trials Directory

Trials / Completed

CompletedNCT06148727

Evaluation of Masticatory Performance and Patient Satisfaction for Conventional and 3D Printed Implant Overdentures

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
16 (actual)
Sponsor
Mansoura University · Academic / Other
Sex
All
Age
50 Years – 70 Years
Healthy volunteers
Accepted

Summary

The aim of this crossover clinical study was the evaluation and comparison of masticatory performance and patient satisfaction for patients rehabilitated with conventional heat cured acrylic resin and 3D printed mandibular implant overdentures retained with bar attachment. it was concluded that 3D printed implant overdenture showed promising results regarding chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdenture.

Detailed description

The aim of this crossover clinical study was the evaluation and comparison of masticatory performance and patient satisfaction for patients rehabilitated with conventional heat cured acrylic resin and 3D printed mandibular implant overdentures retained with bar attachment. Materials and Methods: Twelve completely edentulous healthy participants received new conventional dentures. Four interforaminal implants were inserted in the mandible. After osseointegration, bar was constructed with trapezoidal configuration. Each patient received randomly the following overdentures using a crossover design: conventional heat cured acrylic resin overdenture, 3d printed overdenture ( developed by scanning of mandibular conventional overdenture). Masticatory performance was evaluated with the two-colour mixing ability test after 5, 10, 20, 30, and 50 masticatory cycles. Patient satisfaction was also measured using McGill Denture Satisfaction Questionnaire. Evaluation was done after 3 months of using each overdenture. Conclusion: Within this clinical study limitations, 3D printed implant overdenture showed promising results regarding chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdenture.

Conditions

Interventions

TypeNameDescription
DEVICEDental implant placementProcedure/ surgery: Surgical placement of dental implants, four interforaminal dental implants were placed
DEVICEBar attachmentDevice: attachment, implants were connected to each others by 3 implant assembly in a trapezoidal design implants were loaded after 3 months of osseo-integration Control Group: patients received coventionally constructed heat cured overdenture Study Group: patients received 3d printed overdenture

Timeline

Start date
2023-01-14
Primary completion
2023-07-30
Completion
2023-08-10
First posted
2023-11-28
Last updated
2023-11-28

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT06148727. Inclusion in this directory is not an endorsement.