Live Birth Rate After Sperm Selection Using ZyMōt Multi (850µL) Device for Intra Uterine Insemination

Evaluation of Live Birth Rate After Sperm Selection Using Microfluidic Technology (ZyMōt Multi (850µL) Sperm Separation Device) for Intra Uterine Insemination.

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
240 (estimated)
Sponsor
Universitair Ziekenhuis Brussel · Academic / Other
Sex
All
Age
18 Years – 36 Years
Healthy volunteers
Accepted

Summary

This single centre interventional pilot randomized control study intends to compare two methods of sperm preparation for couples referred for Intra Uterine Insemination (IUI) procedure. Couples will be randomly allocated to one of the two sperm selection methods: Density Gradient Centrifugation (DGC, standard) or ZyMōt Multi (850µL) device (treatment) groups. The study will compare the live birth rate (number of live births per number of IUI procedures) between the treatment and standard groups.

Detailed description

Intrauterine insemination is a commonly used method for Medically Assisted Reproduction for patients with mild male factor infertility, anovulation, endometriosis, and unexplained infertility. It is also the procedure of choice in cases of lesbian couples or single women, using donor sperm. During the IUI procedure, the sperm suspension is introduced into the uterus through the cervix canal using an insemination catheter containing 0.4 ml sperm. Before sperm can be used in IUI, it must first be processed. The aim of semen preparation is to select the best sperm cell population (highly motile, morphologically normal spermatozoa with minimal DNA damage) with the highest fertilization potential. One of the most used sperm preparation technique is DGC. This technique allows the separation of sperm cells based on their density. Morphologically normal and abnormal spermatozoa have different densities. A mature morphologically normal spermatozoon has a slightly higher density, whereas an immature and morphologically abnormal spermatozoon has a lower density. During this procedure, raw semen sample is placed on 2 gradients: a lower phase (80%) and an upper phase (40%) followed by centrifugation. The composition of the gradients include a colloidal suspension of silica particles. At the end of centrifugation, each spermatozoa is situated at the gradient level that matches its density. The highly motile, morphologically normal, viable spermatozoa form a pellet at the bottom of the tube. This procedure is relatively easy to perform but both the centrifugation steps and the silica particle are considered to have a negative impact on DNA integrity. Recently, microfluidic technology was introduced as an alternative to the conventional sperm sorting techniques. As this procedure does not require semen processing, it reduces the sperm preparation time and eliminates sperm DNA damaging procedures (e.g. by centrifugation). This technology is a chemical-free method of sorting healthy normal sperm using a sterile disposable ZyMōt Multi (850µL) sperm separation device. Sperm selected by this device proved to have better motility and less DNA damage compared to DGC procedure. More recently, the efficacy of this device has been reported to significantly increase ongoing pregnancy rate when compared with DGC in IUI cycles. However, large, correct studies that investigate live birth rate are missing. The present study aims to determine whether the use of ZyMōt Multi (850µL) device for sperm selection improves the live birth rate in IUI patients as compared to the standard DGC procedure. Couples undergoing IUI procedure will be included in the study if they are planned for IUI with fresh autologous ejaculate. Patients that fulfill the inclusion criteria will be randomly allocated to one of the two sperm selection methods: DGC (standard) or ZyMōt Multi (850µL) device (treatment) groups. The randomization will be performed based on an electronically generated list. A patient participation to the study will be limited to 3 consecutive IUI attempts (within a period of 6 months). Same semen preparation protocol used in the 1st IUI attempt \[ZyMōt Multi (850µL) or DGC\] will be used in the next 2 consecutive IUIs. Following the IUI procedure (with sperm selected with either one of the two methods), the patients will be monitored for pregnancy, clinical pregnancy and neonatal outcome.

Conditions

Interventions

TypeNameDescription
DEVICEZyMōt Multi (850µL)An amount of 850 µl untreated semen sample will be loaded into the inlet chamber with a help of a sterile insulin-type syringe. A volume of 750 µl of Sage Quinn's AdvantageTM Medium with Hepes + 5% HSA-solution medium will be placed on top of the membrane (outlet chamber). After 30 min of incubation in a humidified incubator (37°C), 500 µl of medium, containing the selected spermatozoa, will be retrieved from the upper side of the membrane (retrieval chamber). An amount of 400 µl will be necessary for the IUI procedure.
OTHERDensity Gradient CentrifugationThe gradient columns will be prepared by placing 1 ml 80% gradient media in a centrifuge tube and an additional 1 ml of 40% gradient layered on top. The raw semen sample will be placed on top of the gradient (1ml semen/gradient tube) and centrifuged at 300xg for 20 minutes. The sperm pellet will be collected and washed 2 times for 5 min at 800xg in Sage Quinn's AdvantageTM Medium with Hepes + 5% HSA-solution. The resulted pellet will be resuspended in the washing solution in a volume that will provide at least 1x106 forward motile spermatozoa in 400 µl, as this amount is necessary for IUI procedure.

Timeline

Start date
2024-01-10
Primary completion
2026-12-01
Completion
2027-12-01
First posted
2023-11-22
Last updated
2024-01-30