Clinical Trials Directory

Trials / Completed

CompletedNCT06127108

Clinical Evaluation of the Panbio™ COVID-19/Flu A&B Panel

Multi-center Clinical Evaluation of the Panbio™ COVID-19/Flu A&B Panel

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
447 (actual)
Sponsor
Abbott Rapid Dx · Industry
Sex
All
Age
2 Years
Healthy volunteers
Not accepted

Summary

The study is designed as a prospective, multicentric, clinical study to investigate the positive percent agreement (PPA) and negative percent agreement (NPA) of the Panbio™ COVID-19/Flu A\&B Panel using anterior nasal swab specimens tested directly, relative to the comparator methods, Roche cobas® SARS-CoV-2 (K231306) and Quidel Lyra® Influenza A+B Assay(K230236) (RT-PCR) in symptomatic patients suspected of respiratory viral infection by a healthcare provider.

Detailed description

Approximately 2,000 symptomatic Participants to achieve at least 80 COVID-19 PCR confirmed positives, 80 Flu A PCR confirmed positives, 80 Flu B PCR confirmed positives, and 500 COVID-19 and Influenza PCR-confirmed negatives. Site staff will collect two (2) anterior nasal swabs from each Participant from whom informed consent has been obtained. Participants ages two (2) years and older meeting eligibility criteria will be enrolled. One anterior nasal swab will be immediately eluted in an extraction buffer tube and tested with the Panbio™ COVID-19/Flu A\&B Panel. If immediate testing is not possible, the swab specimen can be kept in an extraction buffer tube filled with extraction buffer at room temperature (59-86°F /15-30 °C) for up to one (1) hour prior to testing. The other anterior nasal swab will be rotated vigorously in VTM, and the swab head will be left in the VTM, by snapping the shaft or clipping the base of the swab if necessary. Anterior nasal swab sample collection will be as follows: With the swab designated for Panbio testing, use gentle rotation to push the swab into the right nostril until resistance is met at the level of the turbinates (less than one inch into the nostril). Rotate the swab several times against the nasal wall then slowly remove from the nostril. Using the swab designated for PCR testing, repeat sample collection in the left nostril. With the swab designated for PCR testing, use gentle rotation to push the swab into the right nostril until resistance is met at the level of the turbinates (less than one inch into the nostril). Rotate the swab several times against the nasal wall then slowly remove from the nostril. Using the swab designated for Panbio testing, repeat sample collection in the left nostril. The VTM samples will be stored, handled, and tested with comparator assays according to the manufacturers' product instructions. VTM specimens can be stored for up to 48 hours at 2-8°C. If delivery and processing of samples exceeds specified time periods, specimens should be transported in dry ice and once in laboratory frozen at -70°C or colder. Swab eluate samples containing the swab head in VTM will be tested at the central laboratory with the Roche cobas® SARS-CoV-2 (K231306) and Quidel Lyra® Influenza A+B Assay (K230236) per product instructions. All discordant samples (i.e., samples with the Roche cobas® SARS-CoV-2 (K231306) or Quidel Lyra® Influenza A+B Assay (K230236) results that conflict with the Panbio™ COVID-19/Flu A\&B Panel results) will be evaluated with the Hologic SARS-CoV-2/Flu A/B/RSV Assay (Panther Fusion® System) for information only. Samples may also be tested for viral culture. Note: For the purposes of the COVID-19 method comparison, Roche cobas® SARS-CoV-2 results will be interpreted per the package insert. Roche cobas® SARS-CoV-2 results where the ORF1a/b (Target 2) is Negative or Invalid and the E-Gene (Target 3) is Positive are considered Presumptive Positive for COVID-19. These samples will be further evaluated with the Hologic SARS-CoV-2/Flu A/B/RSV Assay (Panther Fusion® System). Each Participant's demographic data, inclusion/exclusion data, days of symptom onset, comparator results, Panbio™ COVID-19/Flu A\&B Panel results and other data elements will be recorded as detailed in Section 10 of this document. Defined Participant data will be recorded on source documentation and entered into an Electronic Data Capture (EDC) system. Panbio™ results and the comparator method results will not be provided to study Participants. Panbio™ COVID-19/Flu A\&B Panel test operators will be blinded to a Participant's standard of care COVID-19 and/or Flu test results.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTPanbio™The Panbio™ COVID-19/Flu A\&B Panel is a visual lateral flow in vitro immunoassay for the qualitative detection of the nucleocapsid protein antigen to SARS-CoV-2, Influenza A, and Influenza B in anterior nasal swab samples from individuals with symptoms and suspected of COVID-19 or Flu infection by their healthcare provider.

Timeline

Start date
2023-11-14
Primary completion
2024-02-02
Completion
2024-02-02
First posted
2023-11-13
Last updated
2024-04-25

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT06127108. Inclusion in this directory is not an endorsement.