"IONTOPHORESIS vs. PHONOPHORESIS" for Treatment of Subacromial Impingement Syndrome

"IONTOPHORESIS vs. PHONOPHORESIS": WHICH IS A BEST WAY TO TREAT SUBACROMIAL IMPINGEMENT SYNDROME? A RANDOMIZED STUDY

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
43 (actual)
Sponsor
Emre Şenocak · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

The aim of this study was to compare the effects of iontophoresis and phonophoresis applications added to conventional treatment on pain, range of motion, disability, and functional status in the shoulder region in patients with subacromial impingement syndrome.

Detailed description

Randomization: Forty-seven patients were assessed, and 43 completed the study in this randomized trial. The participants were divided into two groups (Iontophoresis:22 and Phonophoresis:21) using the online randomization software (www.randomizer.org). All patients gave written informed consent after being verbally informed about the study. Assessment Period: Assessments were conducted twice, at the start and after completion of the 10-session treatment program. Session Period: All treatment programs were delivered five days per week for two weeks. The total number of sessions was ten. Analysis: The statistical analysis was performed using version 21 of the Statistical Package for the Social Sciences (SPSS).To verify normal distribution, the Shapiro-Wilk test and histogram curves were utilized. Descriptive statistics for parametric variables included mean, standard deviation, and percentage. Since the data exhibited normal distribution, independent sample T-tests were used for group comparison while paired sample T-tests were used to detect changes within the group. The significance level of p\<0.05 was deemed acceptable for all analyses. For variables with nominal assessments, data were analyzed utilizing Yates Continuity Correction and Fisher's exact chi-square test. The post hoc power of the study was calculated using Gpower 3.1.9.1 software. The resting VAS scores was taken as reference. In this context, Cohen's effect size was calculated as 1.00. When the alpha error was accepted as 5%, and effect size was 1.00, the post hoc power was found to be 94.27%.

Conditions

Interventions

TypeNameDescription
PROCEDUREIontophoresis InterventionIontophoresis was applied with a Chattanooga Physio (DJO Global, Herentals, Belgium) brand device. The galvanic current mode was selected for the intervention. Intervention area was cleaned to prevent irritation and active electrode pad (cathode-5 cm2) was immersed in 75 mg diclofenac sodium solution. The current intensity of the application for 10 minutes was 0.1-0.2 mA/cm2.
PROCEDUREPhonophoresisPhonophoresis was performed with a Chattanooga brand ultrasound device (Chattanooga, Intelect Legend Ultrasound, TN, USA). 75 mg gel containing 1% diclofenac sodium was applied to the shoulder area. The ultrasound was conducted continuously for 6 minutes with frequency of 1 MHz and an intensity of 1.5 watts/cm2.
PROCEDUREConventional TherapyAll groups received a treatment program consisting of hot pack, Transcutaneous Electrical Nerve Stimulation and Shoulder girdle exercises for 30 minutes.