Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06061757

Use of 4D-ICE in Conjunction With TEE for Left Atrial Appendage Closure

Use of 4D Intracardiac Echocardiography (4D-ICE) in Conjunction With Transesophageal Echocardiography (TEE) for Left Atrial Appendage Closure (LAAC)

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
52 (estimated)
Sponsor
Kansas City Heart Rhythm Research Foundation · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

This is a prospective, single center, non-randomized study with two parallel arms intended to study if 4D Intracardiac echocardiography (4D-ICE) (Nuvision, Nuvera TM) will provide better visualization of the anatomical landmarks from the larger imaging volume and provide optimal intra procedural guidance similar to Transesophageal echocardiography (TEE) (GE 6VT-D ULTRASOUND TRANSDUCER) for Left atrial appendage closure (LAAC). The study will enroll approximately 52 subjects and will be followed through 12 months.

Detailed description

Standard intraprocedural guidance for transcatheter left atrial appendage closure (LAAC) employs a multi-modality integrated approach combining fluoroscopy for guiding the delivery system, and transesophageal echocardiography (TEE) for intracardiac characterization to guide device selection and monitor procedural complications. Successful implantation of the device is confirmed with contrast-enhanced fluoroscopy and color doppler flow imaging on TEE. TEE is the current gold standard for procedural guidance but requires general anesthesia (GA) to avoid patient motion and discomfort during the procedure. General anesthesia, however, is associated with pulmonary complications and patient discomfort due to endotracheal intubation. Intraprocedural LAAC guidance under local anesthesia or conscious sedation might help mitigate these GA-related disadvantages and has motivated multiple clinical studies, establishing intracardiac echocardiography (ICE) as a safe and feasible alternative to TEE. The new generation of NuVision ICE catheter offers a larger imaging volume of 90° x 90° with multiplanar reformatted (MPR) echo views for better visualization of anatomical landmarks and procedural guidance and aid in sizing of the device. This has a potential to improve outcomes and reduce procedure times while lowering healthcare costs. In this study, Role of NuVision Intracardiac Echocardiographic (ICE) catheter with Tranesopheal echocardiography (TEE) in predicting intra-procedural outcomes and success of implantation in patients undergoing left atrial appendage occlusion will be assessed.

Conditions

Interventions

TypeNameDescription
DEVICEImaging guidance with TEE and ICE for Left atrial appendage closureThe occluder size for both LAAC devices will be selected based on the maximal diameter of the LAA orifice following the manufacturer guidelines and using the maximal length of the LAA measured on Echocardiogram. Intraprocedural measurements of the LAA width and depth were acquired on both ICE and TEE per protocol. Both ICE and TEE will be used to assess for any procedural complications prior to insertion of the device delivery sheath.

Timeline

Start date
2023-05-10
Primary completion
2025-12-31
Completion
2025-12-31
First posted
2023-09-29
Last updated
2025-08-28

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT06061757. Inclusion in this directory is not an endorsement.