Evaluation of the Positioning of the Dynacup Cup "One C" Versus "Standard Dynacup"

Evaluation of the Positioning of the Dynacup Cup "One C" Versus Standard Dynacup

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
300 (actual)
Sponsor
Groupe Hospitalier Diaconesses Croix Saint-Simon · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The ceramic-ceramic friction pair is widely used today in total hip arthroplasty, including fourth-generation ceramics which show the lowest wear rate. These have considerably reduced the risk of head fracture compared to previous generations; however, the risk of insert rupture persists with rates similar to those of third generation ceramics. These ceramic fractures require complex revision surgery, which brings complications, exposing patients to the risk of third-body wear and tear related to persistent post-surgical debris. They are frequently due to an incorrect assembly of the ceramic causing intraoperative or early postoperative rupture. To fix this, manufacturers have developed pre-assembled cups in the factory. The Dynacup One C cup developed by Corin® corresponds to the pre-assembled version of the Dynacup cup, making it possible to eliminate the risk of anomaly during intraoperative assembly linked to the human factor and to offer patients with very small cups an adapted ceramic implant. A single study with a small sample compared the two implants (pre-assembled version \[vs\] modular version) clinically, radiologically and functionally without showing any significant difference. The lack of data in the literature comparing these two implants motivated us to conduct a randomized comparative study on a large sample of patients.

Detailed description

Patients eligible for a total hip arthroplasty with a ceramic-ceramic friction couple and scheduled for surgery will be included in this study after information and collection of written consent. After randomization, a preoperative radiograph with a calibration ball will be taken to plan the prosthesis and identify the characteristics of the operated hip. An x-ray of the pelvis with a 28 mm ball will be carried out the day after the intervention according to the same preoperative procedures in order to measure the postoperative radiographic parameters.

Conditions

Interventions

TypeNameDescription
OTHERRandomisation Standard Dynacup or Dynacup One CRandomisation

Timeline

Start date
2021-11-21
Primary completion
2023-03-22
Completion
2023-03-22
First posted
2023-09-25
Last updated
2023-09-25

Locations

1 site across 1 country: France