Trials / Completed
CompletedNCT06024928
Automated Insulin Delivery (AID) for Basal Insulin Titration in Type 2 Diabetes
Short Use of Automated Insulin Delivery (AID) for Basal Insulin Titration in Type 2 Diabetes: A Pilot Study
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 23 (actual)
- Sponsor
- University of Virginia · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this clinical trial is to test the safety and feasibility of using an Automated Insulin Device (AID) in people with Type 2 Diabetes under basal insulin injections to achieve safe and fast basal insulin titration. Participants will be randomized to either the control group or the experimental group. If in the experimental group, the participant will use an insulin pump with Control-IQ Technology (Tandem Diabetes Care) for ten days. Researchers will compare the glycemic control of the experimental group to the control group.
Detailed description
The study will involve 20 people with Type 2 Diabetes who are 18 years or older. The study will be performed at the University of Virginia (UVA), with screening procedures taking place either virtually or at the Clinical Research Unit (CRU) at UVA. All participants will undergo a 10-day run-in phase with a blinded Dexcom Generation 6 Continuous Glucose Monitor (CGM). Participants will be randomized (1:1) to either the Control (CTR) Group or the Experimental (EXP) Group. In the EXP Group, participants will use an Automated Insulin Device (AID) for 10 days in the Basal Insulin Titration (BIT) Phase then return to their original therapy (basal insulin using pen) using the new setting in the Maintenance Phase (MP). The total daily insulin (TDI) requirement during the BIT Phase will be translated to a basal insulin dose. During the same 10 days, in the CTR group, participants will use an unblinded CGM and will be contacted by a study physician as per standard care to adjust their insulin doses if needed. Both groups will then go into a 10-days maintenance period using a blinded CGM. Outcomes will be measured in the last 7 days of the BIT and Maintenance Phases.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Control-IQ use in Type 2 Diabetes under basal insulin injections | Testing the safety and feasibility of using Automated Insulin Delivery (AID) in people with Type 2 Diabetes under basal insulin injections to achieve safe and fast basal insulin titration. |
Timeline
- Start date
- 2024-06-18
- Primary completion
- 2025-12-12
- Completion
- 2025-12-16
- First posted
- 2023-09-06
- Last updated
- 2026-02-17
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT06024928. Inclusion in this directory is not an endorsement.