Clinical Trials Directory

Trials / Completed

CompletedNCT06024928

Automated Insulin Delivery (AID) for Basal Insulin Titration in Type 2 Diabetes

Short Use of Automated Insulin Delivery (AID) for Basal Insulin Titration in Type 2 Diabetes: A Pilot Study

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
23 (actual)
Sponsor
University of Virginia · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this clinical trial is to test the safety and feasibility of using an Automated Insulin Device (AID) in people with Type 2 Diabetes under basal insulin injections to achieve safe and fast basal insulin titration. Participants will be randomized to either the control group or the experimental group. If in the experimental group, the participant will use an insulin pump with Control-IQ Technology (Tandem Diabetes Care) for ten days. Researchers will compare the glycemic control of the experimental group to the control group.

Detailed description

The study will involve 20 people with Type 2 Diabetes who are 18 years or older. The study will be performed at the University of Virginia (UVA), with screening procedures taking place either virtually or at the Clinical Research Unit (CRU) at UVA. All participants will undergo a 10-day run-in phase with a blinded Dexcom Generation 6 Continuous Glucose Monitor (CGM). Participants will be randomized (1:1) to either the Control (CTR) Group or the Experimental (EXP) Group. In the EXP Group, participants will use an Automated Insulin Device (AID) for 10 days in the Basal Insulin Titration (BIT) Phase then return to their original therapy (basal insulin using pen) using the new setting in the Maintenance Phase (MP). The total daily insulin (TDI) requirement during the BIT Phase will be translated to a basal insulin dose. During the same 10 days, in the CTR group, participants will use an unblinded CGM and will be contacted by a study physician as per standard care to adjust their insulin doses if needed. Both groups will then go into a 10-days maintenance period using a blinded CGM. Outcomes will be measured in the last 7 days of the BIT and Maintenance Phases.

Conditions

Interventions

TypeNameDescription
DEVICEControl-IQ use in Type 2 Diabetes under basal insulin injectionsTesting the safety and feasibility of using Automated Insulin Delivery (AID) in people with Type 2 Diabetes under basal insulin injections to achieve safe and fast basal insulin titration.

Timeline

Start date
2024-06-18
Primary completion
2025-12-12
Completion
2025-12-16
First posted
2023-09-06
Last updated
2026-02-17

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT06024928. Inclusion in this directory is not an endorsement.