Clinical Trials Directory

Trials / Completed

CompletedNCT05972148

Precision of Complete-arch Digital Implant Impressions With Intraoral Scanning Versus Photogrammetry

The Accuracy of Intraoral Scanning and Photogrammetry on the Clinical Fit of Long-span Frameworks

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
22 (actual)
Sponsor
William Negreiros · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

The goal of this cross-over clinical trial is to investigate the precision of digital implant impressions using an intraoral scanner and photogrammetry in obtaining complete-arch implant-supported scans. The main question\[s\] it aims to answer are: * Is there a difference in precision between intraoral scans and photogrammetry in obtaining digital implant scans? * Will arch perimeter and jaw type (maxilla vs. mandible) affect the precision results? Procedures: At each appointment, participants existing permanent/temporary prosthesis or healing caps were unscrewed and temporarily removed for the period of the consultation appointment. Scanbodies were screwed into their implants for the duration of the appointment. They underwent two types of digital implant impression procedures (five times each), including intraoral scan and photogrammetry. Intraoral and extraoral photography were taken. At the end of each appointment, the scanbodies were removed, and existing bridge/healing caps were reinserted. The procedures were not painful or required any form of local anesthetic Comparison group: Researchers compared the precision of intraoral scanning vs. photogrammetry to see which device provided the best precision outcomes.

Conditions

Interventions

TypeNameDescription
OTHERDigital scanningFive intraoral scans, one for each arch before the insertion of scanbodies, were obtained. The implant locations were then marked, and the software trimmed a 6mm diameter circular section of the scan from the implant locations to allow the scanbodies to be added. Abutment-level polyetheretherketone (PEEK) scanbodies were hand-tightened onto each implant and not moved for the remainder of the scans. Scanbodies were scanned using a circular scan path, and scanning was finalized.
OTHERPhotogrammetryRectangular-shaped titanium photogrammetry scanbodies were hand-tightened onto the Implants. Scanbodies were not moved before completing all scans for each arch. A total of five scans of each arch were obtained using a photogrammetry device. Measurements were successfully recorded by turning them green on the computer screen.

Timeline

Start date
2019-08-12
Primary completion
2020-09-20
Completion
2022-05-02
First posted
2023-08-02
Last updated
2023-08-03

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT05972148. Inclusion in this directory is not an endorsement.