Trials / Completed
CompletedNCT05948254
Utilized Scan Body Technique For Triple Function
Utilized Scan Body Technique For Jaw Relation Registration And Face Scan Alignment (Triple Function Scan Body)
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 15 (actual)
- Sponsor
- Ain Shams University · Academic / Other
- Sex
- All
- Age
- 22 Years – 45 Years
- Healthy volunteers
- Not accepted
Summary
A triple function scan Body were done on healed dental implant, thus simplifying the workflow for full arch cases and reducing the number of visits to only 3 visits. In this technique, scan bodies were utilized for implant position scanning, facial scan alignment and as stoppers for jaw relation capturing as scan bodies were used as stoppers for jaw relation registration.
Detailed description
The present article describes a novel technique for merging a patient's facial scan with implant scan body and in the same time utilizing the same scan body for recording the jaw relation in only one visit. As a result, a facially driven full-arch implant-supported interim prosthesis can be fabricated first followed by the final restoration in a simplified approach. The aim of this study is to determine whether there is a difference between virtual design and reality using scan body technique (triple function scan body which reflects the accuracy of the scanning protocol. The null hypothesis established that there was consistency between the virtual design and prosthesis in patient's mouth. The scan body was placed in the edentulous arch in the jaw scan step so that bite registration would be easier for the intraoral scanner (IOS) in order to be able to capture both the teeth of the antagonist and part of the scan body in the edentulous jaw simultaneously.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Triple function scan body | The scan bodies were used to scan the implant position, Jaw registration and facial scan alignment, First of all scan bodies were selected according to vertical dimension of occlusion, then the emergence profile together with the selected scan body were scanned,All scan bodies were then removed from the patient mouth except one or even two that were scanned in the jaw scan step, this scan body was utilized as a stopper, the patient was asked to bite until the scan body came in contact with the lower or upper teeth in case of edentulous upper or lower arch respectively, scan body in place (in the same orientation of the previous jaw scan ) provided that at least the tip of the scan body appeared when the patient is asked to smile which would be used as a common area so that the intra oral scanner can relate the jaw scan to the lips and face. |
Timeline
- Start date
- 2022-05-11
- Primary completion
- 2023-04-24
- Completion
- 2023-05-31
- First posted
- 2023-07-17
- Last updated
- 2023-07-17
Locations
1 site across 1 country: Egypt