Real-time Pressure Volume Loop Monitoring as a Guide for Enhanced Understanding of Changes in Elemental Cardiovascular Physiology During Therapeutic Strategies Aiming for Hemodynamic Optimization. Cohort I: Veno-arterial Extracorporeal Membrane Oxygenation (PLUTO-I)

Status
Unknown
Phase
Study type
Observational
Enrollment
20 (estimated)
Sponsor
Erasmus Medical Center · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers

Summary

Invasive pressure-volume (PV) loop measurements have the potential to confirm or refute earlier computer simulations and animal studies regarding changes in cardiovascular physiology induced by (veno-arterial) ECMO. PV loop analysis could create a framework for the (ICU-) clinician for VA-ECMO weaning guidance, based on a patient's individual hemodynamic profile. PV loop measurements may, in future, serve as a guide for which patient would benefit most from (prolonged) VA-ECMO support or which patient would require additional LV unloading. Within the context of PLUTO-I, patients on VA-ECMO support who are eligible for weaning from VA-ECMO will undergo biventricular PV loop measurements on different intensities of extracorporeal support.

Detailed description

Using VA-ECMO support, physiological stability can be maintained in patients with refractory hemodynamic failure as bridge to recovery, definitive therapy or decision making. Previous animal studies and computer simulations hypothesize increased LV afterload as well as RV distention during VA-ECMO. Decision making concerning VA-ECMO weaning is largely based on bedside hemodynamic (including echocardiographic) parameters. Profound details of the effects of VA-ECMO on elemental cardiac physiology, including myocardial metabolic efficiency and ventricular-arterial coupling, are limited. We hypothesize biventricular pressure-volume loop (PVL) measurement will enhance understanding of elemental cardiovascular physiology including ventricular interdependence during different levels of VA-ECMO support. PVL measurement will hypothetically provide opportunities in discovering novel predictors for successful weaning from VA-ECMO support. For the purpose of PLUTO-I, patients on VA-ECMO who are eligible to wean will undergo invasive PV-loop measurements on different intensities of extracorporeal flow.

Conditions

Interventions

TypeNameDescription
OTHERPressure-volume loop measurementsPressure-volume loop measurements using a conductance catheter

Timeline

Start date
2022-11-14
Primary completion
2024-11-14
Completion
2024-12-14
First posted
2023-06-18
Last updated
2024-01-05