Clinical Trials Directory

Trials / Unknown

UnknownNCT05830578

Clinical Validation of the Electrocardiogram Measurement

Clinical Validation of the Electrocardiogram Measurement and Atrial Fibrillation Detection Function of a Wearable Smartwatch

Status
Unknown
Phase
Study type
Observational
Enrollment
602 (estimated)
Sponsor
Taipei Medical University Hospital · Academic / Other
Sex
All
Age
22 Years
Healthy volunteers
Accepted

Summary

Atrial fibrillation (AFib) is a common type of cardiac arrhythmia in clinical practice, affecting millions of people worldwide. Early detection and treatment of atrial fibrillation are crucial in preventing serious complications such as stroke and heart failure. In recent years, with the flourishing development of wearable devices and mobile technology, electrocardiogram (ECG) measurement applications embedded in smartwatches have gradually become a non-invasive and convenient method for heart rate monitoring. However, the accuracy of these devices has not yet been fully determined. This study aims to verify the ECG measurement and atrial fibrillation detection function of the ASUS Blood Pressure Monitor/Oximeter/ECG Monitor. The accuracy of the ECG application in detecting atrial fibrillation and measuring ECG will be evaluated by comparison with standard 12-lead ECGs.

Detailed description

This study plans to recruit 602 adults over the age of 22. All participants will undergo heart rate measurements using both the smartwatch ECG application and the 12-lead ECG. The heart rate measurement using the ECG application will be operated by the participants themselves under the guidance of the testing personnel. The 12-lead ECG will be operated by trained medical professionals. The results of the heart rate measurement from both devices will be recorded synchronously, and the consistency of heart rate interpretation and ECG waveforms between the smartwatch ECG application and the 12-lead ECG measurement will be compared to verify the accuracy of the ECG application.

Conditions

Interventions

TypeNameDescription
DEVICEASUS Blood Pressure Monitor/Oximeter/ECG MonitorThe ASUS Blood Pressure Monitor/Oximeter/ECG Monitor analyzes data collected by the integrated electrical sensors on a ASUS Vivowatch to generate an ECG waveform similar to a Lead I, calculate average heart rate, and provide a rhythm classification to the user for a given 30 second session. When a user opens the ECG App while wearing the ASUS VivoWatch on one wrist and places the finger of the opposite hand on the digital crown, they are completing the circuit across the heart which begins a recording session. Once the recording session is complete, the ECG App performs signal processing, feature extraction and rhythm classification to generate a session result.

Timeline

Start date
2023-12-01
Primary completion
2024-06-30
Completion
2024-12-30
First posted
2023-04-26
Last updated
2023-11-24

Source: ClinicalTrials.gov record NCT05830578. Inclusion in this directory is not an endorsement.