Trials / Unknown
UnknownNCT05812664
The Effects of Bolus, Intermittent and Continuous Enteral Feeding on Blood Glucose and Feeding Intolerance in ICU Patients With Sepsis
The Comparison of Effects of Bolus, Intermittent (Nocturnal Pause) and Continuous Enteral Feeding Methods on Blood Glucose and Feeding Intolerance in ICU Patients With Sepsis, Prospective, Randomized, Controlled Study
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 93 (estimated)
- Sponsor
- Umraniye Education and Research Hospital · Other Government
- Sex
- All
- Age
- 18 Years – 70 Years
- Healthy volunteers
- Not accepted
Summary
Comparison of the effects of bolus, intermittent and continuous enteral feeding techniques on plasma glucose level and enteral feeding intolerance in adult intensive care unit patients with sepsis.
Detailed description
in this prospective, controlled trial the main aim is to evaluate the effects of bolus, intermittent and continuous enteral feeding techniques on plasma glucose level in intensive care patients with sepsis diagnosis and to determine whether they are superior to each other in providing norma-glycemia. The secondary aim is to determine the effect of these 3 different enteral feeding techniques on enteral feeding intolerance.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | enteral feeding | The amount of enteral nutrition that should be given daily was calculated by the nutritionist using the Harris-Benedict formula. Formula at room temperature was given with a nasogastric foley catheter and a feeding pump. The position of the nasogastric Foley catheter in the stomach was confirmed by the PAAC graph when it was first inserted, and by listening before each feeding. Feeding was done in a position with the head at 30 degrees. |
| PROCEDURE | blood glucose measurements | Blood glucose values were measured in all groups at 06:00, 12:00, 18:00 and 24:00, 4 times a day for 7 days. The sample was taken from the patient's cannula and examined in the biochemistry lab. The targeted range in the measurements was accepted as 70-180 mg/dl. |
| PROCEDURE | Evaluation of feeding intolerance with gastric residue | gastric residue assessment; 30 minutes after the feeding was stopped, the N/G tube was drained and the amount coming 30 minutes later was evaluated. Residue positive was defined as the return of more than half of the amount of formula in the last cycle. The same was continued without increasing the amount given. If the incoming amount was less than half, the residue was evaluated as negative and the formula was continued by increasing the predetermined amount. |
Timeline
- Start date
- 2023-12-01
- Primary completion
- 2023-12-01
- Completion
- 2023-12-01
- First posted
- 2023-04-14
- Last updated
- 2023-12-13
Locations
1 site across 1 country: Turkey (Türkiye)
Source: ClinicalTrials.gov record NCT05812664. Inclusion in this directory is not an endorsement.