Trials / Unknown
UnknownNCT05798325
Feasibility, Validation and Application of Digital Tools for the Follow-up of Neuromuscular Patient Mobility in Daily Living
Feasibility, Validation and Application of Digital Tools for the Follow-up of Neuromuscular Patient
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 40 (estimated)
- Sponsor
- Institut de Myologie, France · Academic / Other
- Sex
- All
- Age
- 12 Years – 60 Years
- Healthy volunteers
- Not accepted
Summary
The low prevalence of rare diseases hinders the design of clinical studies with sufficient statistical power to demonstrate the efficacy of new drugs. This can only be achieved by setting up international multicentre studies, which is challenging due to a lack of objective, universal outcome measures that generate high-quality, reproducible data. One of the hurdles in attaining universal outcome measures for clinical trials is the difficulty to capture and distinguish ambulatory from non-ambulatory, autonomous and assistive or involuntary movements. This makes a trial assessing the ambulatory phase very challenging at this moment. Excluding many participants from trials and many patients from access to medication. Integration and validation of the technology in trials, research and patients' lives is essential in overcoming this hurdle. For example, in dystrophinopathies separate outcome measures exist for ambulant and non-ambulant participants, but the relation between these outcome measures or a transitional outcome measure/end point is largely missing. Following an exhaustive literature review, several tools have been selected to remotely follow various symptoms of neuromuscular patients including weakness, pain, fatigue, cognitive defects, motor impairments (including loss of dexterity, ataxia...), metabolic, respiratory and cardiac troubles, contractures, tremor, falls, hypo or hypersomnia... The toolbox includes common measures for all patients but may include additional measures specific to the patient's symptoms (hence in turn to the patients' disease). The measurements are designed to not be invasive, intrusive or burdensome for the patient. DT4RD is going to leverage state-of-the art technology, clinical rating scales and psychometric/data analysis to deliver fit for purpose remote clinical assessments of mobility to ensure maximum patient benefit, specifically: * Compare face to face clinical data collected in hospital with Patient Generated Data recorded remotely * Examine how sensors can enhance measurement potentially at home and during clinical visits * Promote a clear focus on user centered design and the integration of technology * Use reliability and validity analyses to equate any common measures (those with the same or a similar construct) * Demonstrate a proof-of-concept model into which different measures can be interchangeable
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | 2MWT | Two minutes walk tests. |
| OTHER | MFM32 | Motor Function Measurement (MFM) is a quantitative scale created to measure global motor functional abilities in a person with neuromuscular disease. |
| OTHER | MyoGrip | The MyoGrip is a dynamometer for measuring grip strength. |
| OTHER | QOL-gNMD | The "Quality of Life in genetic Neuromuscular Disease" questionnaire (QoL-gNMD) is a patient reported outcome measure (PROM) tool specifically designed for patients with a lowly progressive neuromuscular disease with genetically predominant muscular damage |
| DIAGNOSTIC_TEST | Spirometry | Forced vital capacity (FVC), peak expiratory flow (PEF) and forced expiratory volume in 1 second (FEV1) will be measured in the hospital with the local hospital device (e.g. Vitalograph) under the supervision of the clinical evaluator, and at home with a portable device. |
| DEVICE | Acceleromerty | The Links sensor system is a measuring device and consists of the Links Pods and the Links Hub. The Links pods contain an accelerometer, gyroscope and magnetometer to measure position relative to a global reference frame. |
| OTHER | 10mWT | 10 meters walking Test. |
| OTHER | PUL | The Performance of the Upper Limb (PUL) is a functional scale specifically designed for assessing upper limb function in Duchenne muscular dystrophy. |
| OTHER | NSAA | The North Star Ambulatory Assessment (NSAA) is a 17-item rating scale that is used to measure functional motor abilities in ambulant children with Duchenne Muscular Dystrophy. |
| OTHER | NSAD | The NSAD was developed to measure motor performance in ambulant and non-ambulant subjects as part of the clinical outcome study of dysferlinopathy. |
| OTHER | TANS | This scale is derived from the North Star Ambulatory Assessment and several items from the Egan Klassifikation Scale (EK2). |
| OTHER | MyoPinch | The MyoPinch is a high-precision dynamometer that allows the evaluation of key pinch strength. |
| OTHER | MyoQuad | The MyoQuad is a high-precision dynamometer that allows the evaluation of knee extension strength. |
| OTHER | ACTIVLIM | Activity limitations, as measured by ACTIVLIM, is defined as the difficulties a patient may have in executing daily activities, whatever the strategies involved. |
| OTHER | PREM | This questionnaire is made up of simple questions relating to the assessments and assessment tools that were used during the study. |
| OTHER | SF-MPQ | The main component of the SF-MPQ consists of 15 descriptors (11 sensories; 4 affective) which are rated on an intensity scale as 0 = none, 1 = mild, 2 = moderate or 3 = severe. |
| OTHER | FSS | The Fatigue Severity Scale is used to assess the severity of fatigue and its impact on daily living. The patient responds on a Likert-type scale ranging from 1 to 7. |
| OTHER | IPAQ | This questionnaire assesses overall physical activity and the level of sedentary lifestyle during the last seven days. |
| OTHER | Rang of motion | The EasyAngle® is a digital goniometer improving long established goniometric functionality with rotation, inclination, and scoliosis measurement capabilities. |
| DEVICE | Goniometry | The Links sensor system is a measuring device and consists of the Links Pods and the Links Hub. The Links pods contain an accelerometer, gyroscope and magnetometer to measure position relative to a global reference frame. |
| OTHER | Video captured monitoring | Once every four weeks, while wearing the Yumen electronic goniometers (Links Sensor System), the patients will be asked to record on video three tasks related to: 1. Upper limbs: hands to head 2. Lower limbs: Sit to stand with or without the help of a person 3. Self-defined important task: A task of the patient's choice, from a list of tasks, representative of his/her motor difficulties or hindrance to autonomy. |
| DEVICE | Activity monitoring | Wearable devices (connected watch) will collect health-related data on a 24/7 basis remotely as patients go through their daily routines at home and work. |
Timeline
- Start date
- 2023-06-29
- Primary completion
- 2024-06-30
- Completion
- 2024-06-30
- First posted
- 2023-04-04
- Last updated
- 2023-09-28
Locations
2 sites across 2 countries: France, United Kingdom
Source: ClinicalTrials.gov record NCT05798325. Inclusion in this directory is not an endorsement.