Trials / Not Yet Recruiting
Not Yet RecruitingNCT05792397
TwiFlow Thrombectomy Catheter sYstem for Acute Pulmonary Embolism (Twi-TYPE Study)
A Multicenter Prospective Single-arm Study to Evaluate the Safety and Efficacy of a Novel Transcatheter Pulmonary Thrombectomy System Which Named 'TwiFlow' for Acute Pulmonary Embolism
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 127 (estimated)
- Sponsor
- Morningside (Nantong) Medical Co.,Ltd · Academic / Other
- Sex
- All
- Age
- 18 Years – 75 Years
- Healthy volunteers
- Not accepted
Summary
As a multicenter prospective single-arm clinical study, the investigators plan to recruit patients with acute pulmonary intravascular embolization from nationwide multi-center hospital organizations in China. The investigators use the production of transcatheter pulmonary artery bolt system which named 'TwiFlow Thrombectomy Catheter System' developed by the MorningSide (NanTong) medical device Co., LTD. on pulmonary artery interventional therapy to evaluating the efficacy and safety of this novel system in the treatment of patients with pulmonary intravascular embolization disease.
Detailed description
As a multicenter prospective single-arm clinical study, the investigators plan to evaluate the new production's efficacy and safety which named 'TwiFlow-Thrombectomy Catheter System'. This study will be carried out in nationwide multi-center hospital organizations in China. According to the statistical principle, the sample size of this study was estimated, and the final number of selected cases was 127. After screening, all subjects will be treated with transcatheter pulmonary artery thrombectomy system, and clinical follow-up will be conducted at 48 hours, 14 days and 30 days after surgery. Right Ventricular/Left Ventricular decline from baseline to 48 hours after surgery and the incidence of major adverse events (MAE) within 48 hours after surgery were used as primary endpoints. In instrument performance evaluation, the success rate of surgery, postoperative immediate target lesion embolus removal efficiency, pulmonary artery pressure changes before and after operation value, values of arterial oxygen partial pressure changes before and 14 days after operation, death rates related to the equipment in 48 hours after surgery, incident rate of bleeding in 48 hours after operation, postoperative clinical deterioration rate in 48 hours after surgery, postoperative pulmonary vascular injury incidence in 48 hours after surgery, the incidence of heart damage injury in 48 hours after surgery, all-cause death rate in 30 days after surgery, and symptomatic Pulmonary Embolization recurrence rate in 30 days after surgery were secondary endpoints.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | TwiFlow-Thrombectomy Catheter System | Patients with acute pulmonary embolism and meeting the conditions of this clinical trial will accept the pulmonary embolism removal operation by the novel device named 'TwiFlow-Thrombectomy Catheter System' |
Timeline
- Start date
- 2023-05-01
- Primary completion
- 2024-05-01
- Completion
- 2026-05-01
- First posted
- 2023-03-31
- Last updated
- 2023-03-31
Source: ClinicalTrials.gov record NCT05792397. Inclusion in this directory is not an endorsement.