Trials / Terminated
TerminatedNCT05785949
Chondro-Gide® Bilayer Collagen Membrane in Knee Cartilage Defect Repair
A Prospective, Multicenter, Randomized, Parallel Controlled Study Evaluating the Safety and Efficacy of Chondro-Gide® Bilayer Collagen Membrane in Knee Cartilage Defect Repair
- Status
- Terminated
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 75 (actual)
- Sponsor
- Geistlich Pharma AG · Industry
- Sex
- All
- Age
- 18 Years – 55 Years
- Healthy volunteers
- Not accepted
Summary
A prospective, multicenter, randomized, parallel controlled study evaluating the safety and efficacy of Chondro-Gide® bilayer collagen membrane in knee cartilage defect repair. The objective of this clinical trial is to evaluate the efficacy and safety of Chondro-Gide® bilayer collagen membrane in knee cartilage defect repair
Detailed description
This is a prospective, multicenter, randomized, parallel controlled and superiority clinical trial. It is planned to be carried out in hospitals with qualifications as a national-level clinical trial institution. Subjects who have signed the ICF, meet all inclusion criteria and do not meet any exclusion criteria will be included in this study. Subjects included will be randomly assigned into the experimental group and the control group at a ratio of 1:1. Those in the control group will receive microfracture, and those in the experimental group will receive microfracture plus Chondro-Gide® bilayer collagen membrane. The primary efficacy evaluation indicator of this clinical study is the MOCART score at 24 months postoperative. The secondary efficacy evaluation indicators are IKDC score (before operation, 3, 6, 12 and 24 months postoperative), MOCART score (6 and 12 months postoperative), hyaline cartilage production (T2 mapping ratio) (12 and 24 months postoperative), Lysholm score (before operation, 3, 6, 12 and 24 months postoperative), and device performance evaluation of the investigational product. Safety evaluation indicators include adverse events (or serious adverse events), device-related adverse events (or serious adverse events), device deficiencies and laboratory examination.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Microfracture | Use of standard tool kit to drill vertically from the periphery to the center with a hole spacing of 3\~4 mm with care to prevent penetrating adjacent holes. The hole depth should be 3\~5 mm and fat droplets or blood oozing is seen after loosening the tourniquet. However, no blood oozing is observed in some holes and in such case, the hole depth should be deepened to 5\~7 mm. |
| DEVICE | Chondro-Gide bilayer collagen membrane | After the Microfracture, the porous layer of the bilayer collagen membrane faces the bone surface. The already trimmed, cut and wetted membrane is insert into the defect and fixed symmetrically with absorbable surgical suture with needle. Knots are put on the pinhole of collagen membrane to avoid tearing of surrounding cartilage or collagen membrane during knotting. |
Timeline
- Start date
- 2023-03-10
- Primary completion
- 2025-12-04
- Completion
- 2026-01-31
- First posted
- 2023-03-27
- Last updated
- 2026-03-09
Locations
18 sites across 1 country: China
Source: ClinicalTrials.gov record NCT05785949. Inclusion in this directory is not an endorsement.