Detecting Syncope by an Integrated Multisensor Patch-type Recorder

Detection of Impending Reflex Syncope by Means of an Integrated Multisensor Patch-type Recorder

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
50 (actual)
Sponsor
Istituto Auxologico Italiano · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The main purpose of this study is to assess the reliability of a new cuffless patch BP monitor in detecting episodes of hypotensive (pre)syncope during tilt testing.

Detailed description

Background While ECG monitoring is a reliable and established method that allows to document bradycardia in a substantial proportion of patients affected by cardioinhibitory reflex syncope, the documentation of a transient hypotension is only seldom achieved in patients affected by hypotensive syncope. Conventional ambulatory blood pressure (BP) monitoring (ABPM) has important limitations due to the short period of monitoring (usually 24-48 hours) and the intermittent nature of BP measurements (usually every 15-20 min). The main purpose of this study is to assess the reliability of a new cuffless patch BP monitor in detecting episodes of hypotensive (pre)syncope. Secondary aim regards the estimation of feasibility of this tool. Method The study is a prospective intrapatient comparison between BP measured by mean of a cuffless patch BP monitor (RootiRX System, Rooti Labs Ltd., Taipei, Taiwan) and by mean of the standard method during tilt testing. Study design BP values observed during tilt testing baseline and at the time of impeding syncope will be measured by mean of the RootiRX device and will be compared with the standard of reference. BP will be recorded at rest at baseline, shortly after upright in tilting position (at stabilization), at the time of occurrence of syncope (presyncope) or, alternatively at the time of maximum hypotensive effect, if syncope will not occur, and finally in the recovery period at the end of the test after returning in supine position.

Conditions

Interventions

TypeNameDescription
DEVICEBP monitoring during tilt testingBP measure at various times during tilt testing