Clinical Trials Directory

Trials / Unknown

UnknownNCT05754476

Multi-center Study of Artificial Intelligence Model for Gadolinium-based Contrast Agent Reduction in Brain MRI (MAGNET)

Multi-center and Prospective Cohort Study of Artificial Intelligence Model for Gadolinium-based Contrast Agent Reduction in Brain MRI (MAGNET)

Status
Unknown
Phase
Study type
Observational
Enrollment
3,000 (estimated)
Sponsor
Beijing Tiantan Hospital · Academic / Other
Sex
All
Age
Healthy volunteers
Accepted

Summary

MAGNET is a multi-center and prospective study to minimize Gadolinium-based Contrast Agent (GBCA) combining novel artificial intelligence (AI) methods with pre-contrast images and/or low-dose images to synthesize virtual contrast-enhanced T1 (vir-T1c) images, based on a large clinical and MRI database and subsequently validated for its clinical value. MRI examinations for patients included T1-weighted images (T1WI) before and after contrast agent administration and at two dose levels: low-dose (10% or 25%) and full-dose (100%), T2-weighted images (T2WI), fluid-attenuated inversion recovery (FLAIR), and diffusion-weighted imaging sequences (DWI) and the computed apparent diffusion coefficient (ADC), all either acquired three dimensional \[3D\] or two dimensional \[2D\]). The standard dose of intravenous gadolinium contrast agent was 0.1mmol/kg(body weight) by manual injection or automatic injection with a high-pressure syringe at a flow rate of 4mL/s.The sequence parameters used for the 3DT1WI scans must be consistent, and the standard for intravenous injection of gadolinium contrast agent is 0.1mmol/kg (body weight), administered either manually or automatically with a high-pressure syringe at a rate of 4mL/s. Additionally, arterial spin labeling (ASL), amide-proton transfer chemical exchange saturation transfer (APT-CEST), susceptibility-weighted imaging (SWI), or quantitative susceptibility mapping (QSM) can be acquired at the same time if the conditions permit.

Detailed description

MRI with GBCA is an indispensable part of imaging exams for brain disease diagnosis. Generally, GBCA is safe, with a few mild side effects since GBCAs received FDA approval in 1989. There are numerous issues that challenge the current practice of widespread use of GBCA. GBCA can trigger nephrogenic systemic fibrosis(NSF) under particular circumstances, cause allergic reactions, may increase the risk of fetal death, and accumulate in the brain such as the dentate nucleus and globus pallidus. Efforts need to be made to reduce dose while still maintaining diagnostic capabilities. Artificial intelligence (AI) techniques have shown great potential in medical fields. Deep learning (DL), a branch of AI, has been applied to image segmentation, computer-aided diagnosis, and reduce GBCA dose. This study intends to build a prospective brain MRI dataset including patients with suspected or known brain abnormalities to minimize the use of GBCA. Then train DL models to process pre-contrast images and/or low-dose T1 images to predict virtual contrast-enhanced T1 (vir-T1c) images, taking the full-dose images as the reference standard. Later quantitatively and qualitatively evaluating and comparing vir-T1c images from DL models about clinical diagnostic performance, focusing on lesion detection, diagnosis, and therapy, to explore a DL model universal, provide enhanced images faster and more convenient in clinical practice. To minimize the use of GBCA, we will: 1. Use novel artificial intelligence (AI) methods with pre-contrast images including conventional (T1WI, T2WI, FLAIR, DWI/ADC), new physiological MRI techniques (ASL, APT-CEST, SWI/QSM) by adding physiological information from perfusion as well as metabolic and susceptibility imaging, and/or low-dose images (10% or 25%) to synthesize vir-T1c images; 2. Quantify when (in which patients and at what follow-up times) GBCA can be omitted or minimized without influencing brain disease diagnosis and treatment evaluation for doctor raters and therefore patient prognosis. This study does not limit manufacturers including 1.5T and 3.0T scanners, or kinds of GBCAs.

Conditions

Interventions

TypeNameDescription
OTHERLow-dose GBCA levelsMRI examinations for patients at two dose levels: low-dose (10% or 25%)can be chosen.

Timeline

Start date
2019-03-29
Primary completion
2023-12-31
Completion
2024-12-31
First posted
2023-03-03
Last updated
2023-03-03

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT05754476. Inclusion in this directory is not an endorsement.