Trials / Completed
CompletedNCT05739058
Violet-Blue Light Inactivation of Bacteria in Chronic Wounds
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 22 (actual)
- Sponsor
- Bispebjerg Hospital · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This four-week prospective clinical investigation will assess the safety and feasibility of a medical device without CE-marking. The medical device is a light-emitting-diode (LED) and is manufactured by VulCur MedTech Aps. Violet-blue light treatment is tested on a total of twenty-two patients with chronic wounds, divided into three groups, each group only receiving one dosage. Three dosages (low, medium and high) of violet-blue light treatment is tested. ID 1-7 are assigned to the low group, ID 8-15 are assigned to medium group and ID 16-22 are assigned to the high dosage group.
Detailed description
This is as prospective safety and feasibility clinical trial investigating violet-blue light treatment on chronic wounds. This clinical trial runs from Q3 2022 - Q2 2023. Twenty-two patients with chronic wounds will be included (n = 22) for a study-period of four weeks. Week 1 includes one baseline visit. Through Week 2,3 and 4 treatment is given six times with a span of 24-72 hours between every treatment visit. Week 4 includes one follow up-visit. Patients entering the study are assigned to three light dosage groups (low, medium and high) according to their study ID. ID 1-7 are assigned to the low group, ID 8-15 are assigned to medium group and ID 16-22 are assigned to the high dosage group. Between each dosage of light, there will be an evaluation of primary and secondary endpoints by the sponsor and the principal investigator. Light dosage is only escalated should this evaluation be deemed safe. To determine treatment safety skin reactions are assessed after treatment at: 0 minutes, 30 minutes, 24 hours, 48 hours, 5th treatment visit and at follow-up. Adverse Events and Adverse Device Events are evaluated at every visit for every dosage, feasibility is evaluated at follow-up for both patient and investigator. This investigation complies with the Good Clinical Practice concerning medical devices and follows the ISO standard DS/EN 14 155 and the Declaration of Helsinki
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Violet-Blue Light Treatment / FlashHeal Device | FlashHeal illuminates an area of 10 cm in diameter, located at 6-7 cm distance of the wound. Wounds larger than 10 cm in diameter, will receive enough treatments to cover the wound bed. To obtain full coverage the circular treatment area is relocated to cover the remaining wound field. The wavelength is 405 nm, Full Width Half Maximum at (FWHM) 400-415 nm. Device irradiances are adjusted to the total fluences required for the Low, Medium and High group, the treatment will last 15 minutes at all dosages. Light is emitted with 1000 Hz. |
Timeline
- Start date
- 2023-03-22
- Primary completion
- 2024-05-01
- Completion
- 2024-05-01
- First posted
- 2023-02-22
- Last updated
- 2024-05-03
Locations
1 site across 1 country: Denmark
Source: ClinicalTrials.gov record NCT05739058. Inclusion in this directory is not an endorsement.