Clinical Trials Directory

Trials / Completed

CompletedNCT05717244

Comparison of Two Different Pupillometer

Comparison of Two Pupillometer for Determining Pupil Diameter in Healthy Participants

Status
Completed
Phase
Study type
Observational
Enrollment
100 (actual)
Sponsor
He Eye Hospital · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

With the development of refractive surgery, the size of scotopic pupil has been widely concerned by clinicians. Historically, the measurement of pupil size included the use of a pupil ruler, which is known for its drawback of being very subjective and lacking precision. While infrared pupillometry devices such as OPD-Scan III and Sirius are available for accurately and reliably measuring pupil size. Nevertheless, the aforementioned equipments are costly and cumbersome to move in terms of screening and field trial logistics settings. And 2WIN-S is a portable refractor, it can in a short period of diopter and scotopic pupil size and other data obtained at the same time. Therefore, the aim of this study was to compare the agreement between 2WIN-S and OPD-Scan III in measuring scotopic pupil size and the repeatability of 2WIN-S.

Detailed description

Pupil diameter is a parameter of great interest in understanding brain systems and modern refractive surgery. Pupillometry, the measurement of variations in pupil dilation, has offered encouraging evidence for the involvement of disturbed reactivity in depression risk, according to studies. According to research, the pupil dilates in reaction to stimuli requiring a larger cognitive load or a greater emotional intensity. Importantly, studies have related pupil size variations to brain activity in regions associated with emotion regulation, including the dorsolateral prefrontal cortex (DPFC) and the agenesis of the corpus callosum (ACC) . Thus, pupillometry is proposed as a viable peripheral gauge for a variety of brain systems involved in the processing of emotional information. Some of the postoperative complaints of patients having refractive corneal or lens surgery are related to visual quality and are associated with large pupils since optical aberrations become more dominant when the pupil dilates . If the pupil size exceeds the optical zone size, a marked increase in higher-order aberrations could be observed. Patients might complain about poor contrast sensitivity, increased glare disability, or halos. Precise measurement of scotopic pupil diameter has therefore become an essential step in the preoperative evaluation of patients suitable for refractive surgery and is an important inclusion or exclusion criterion. This study aimed to assess the agreement and reproducibility of scotopic pupil size measurements using 2WIN-S compared with OPD-Scan III in Chinese adults.

Conditions

Interventions

TypeNameDescription
DEVICE2WIN-SDetermining pupil diameter by 2WIN-S
DEVICEOPDDetermining pupil diameter by OPD

Timeline

Start date
2023-09-01
Primary completion
2023-12-20
Completion
2024-02-01
First posted
2023-02-08
Last updated
2024-06-24

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT05717244. Inclusion in this directory is not an endorsement.