Trials / Completed
CompletedNCT05601076
Small-diameter Closed Thoracic Drainage Tube Fixation Method
Design and Application of Small-diameter Closed Thoracic Drainage Tube Fixation Following Lung Wedge Resection: a Randomised Prospective Study
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 139 (actual)
- Sponsor
- Taizhou Hospital of Zhejiang Province affiliated to Wenzhou Medical University · Academic / Other
- Sex
- All
- Age
- —
- Healthy volunteers
- Accepted
Summary
Objective: To explore the design feasibility and application effect of triple-buffer-system-fixed small-diameter (18 F) thoracic closed drainage tubes following lung wedge resection. Methods: A total of 136 patients with indwelling thoracic drainage tubes following pulmonary wedge resection were recruited, with 70 patients allocated to the control group and 66 to the experimental group. The drainage tube in the experimental group was fixed with the triple-buffer system, while that in the control group was fixed using the conventional lifting platform method. The incidence of unplanned extubation, the indwelling time of the drainage tube and the time and material costs, as well as information regarding any subcutaneous emphysema and skin tension blisters, were recorded following the operation. The pain and degree of comfort were assessed using a chi-square test and a rank sum t-test to compare the differences between the two groups.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | fixed with the triple-buffer system | The steps were as follows: i) elastic cotton tape (3M 2733-25 Japan Ltd., Tokyo, Japan) was used at the proximal 15 cm from the incision, with 5 × 2.5 cm pieces glued to the skin and fixed with the drainage tube using surgical knots; ii) the distal end of the ligation was fixed using the same method, while the ligation position was higher than the first; iii) the ligature point was fixed next to the elastic soft cotton tape (5 × 5 cm), using the high-platform method to fix the drainage tube, with the drainage tube curved; and iv) the drainage tube between the two fixed points was inserted with a specific radian. |
| PROCEDURE | fixed using the conventional lifting platform method | In terms of the control group, two lines of flexible cotton tape (3M 2733-25 Japan Ltd., Tokyo, Japan) measuring 10 × 2.5 cm were used, and the drainage tube was fixed parallel to the long axis and glued to the middle-position 360° winding tube once the drainage tube was 0.5 cm higher than the surrounding skin. Next, the drainage tube was fixed at both ends to the patient's skin using adhesive tape. Then, the tube and the adhesive plaster were overlapped vertically and horizontally, the tube was inserted, the adhesive plaster was added, and then the chest tube was fixed on the adhesive plaster by knotting the interspersed cotton rope, which was equal to indirectly fixing the tube on the patient's skin |
Timeline
- Start date
- 2019-02-02
- Primary completion
- 2021-08-30
- Completion
- 2022-07-30
- First posted
- 2022-11-01
- Last updated
- 2022-11-01
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT05601076. Inclusion in this directory is not an endorsement.