Trials / Completed
CompletedNCT05576194
Taurolidine Containing Antimicrobial CIED Wash to Prevent Infection
Effect of Intraoperative Topical Application of a Taurolidine Solution on CIED Related Infections in the Clinical Setting - a Prospective Observational Study With a Restrospective Historical Control
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 1,417 (actual)
- Sponsor
- Prof. Dr. Hendrik Bonnemeier · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- —
Summary
From January 1st 2020, any CIED procedure conducted with adjunct TauroPace™ CIED and pocket irrigation is enrolled in a consecutive manner and followed up in one centre. Follow-up is prospectively. Before that date any CIED procedure conducted with adjunct antispetic pocket and CIED irrigation is evaluated retrospectively to form a comparable group.
Detailed description
All the hardware (leads, suture sleeves, pulse generator) is washed and the device pocket irrigated with an adjunct antimicrobial solution, which could be 3% hydrogen peroxide (H2O2), taurolidine in a galenic formulation or TauroPace™ (TP, Tauropharm, Bavaria, Germany), during any invasive procedure (new implantation, pulse generator replacement, lead repositioning or insertion, system upgrade or downgrade, revision) involving a CIED system at the authors' institute. Before 01/01/2020, the choice of antimicrobial solution was at the operator's discretion. These procedures were evaluated retrospectively. With change of policy on the first of January 2020, in every consecutive patient and procedure only TP is used. Patients were enrolled and followed consecutively in order of appearance. All CIED procedures performed at the author's institute between 01/01/2017 and 28/02/2022 are included for analysis. Patients who receive the galenic taurolidine formulation were excluded from analysis.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | TauroPace | All the hardware (leads, suture sleeves, pulse generator) is washed and the device pocket irrigated with an adjunct antimicrobial solution containing Taurolidine (TauroPace™, Tauropharm, Bavaria, Germany), during any invasive procedure (new implantation, pulse generator replacement, lead repositioning or insertion, system upgrade or downgrade, revision) involving a CIED system since January 2019 |
| DEVICE | Hydrogen Peroxide | All the hardware (leads, suture sleeves, pulse generator) was washed and the device pocket irrigated with an adjunct antimicrobial solution containing 3% hydrogen peroxide (H2O2) during any invasive procedure (new implantation, pulse generator replacement, lead repositioning or insertion, system upgrade or downgrade, revision) involving a CIED system at the authors' institute before 01/01/2020 |
| DRUG | Taurolidine | All the hardware (leads, suture sleeves, pulse generator) was washed and the device pocket irrigated with an adjunct antimicrobial solution containing taurolidine in a galenic formulation during any invasive procedure (new implantation, pulse generator replacement, lead repositioning or insertion, system upgrade or downgrade, revision) involving a CIED system at the authors' institute before 01/01/2019 |
Timeline
- Start date
- 2020-01-01
- Primary completion
- 2022-03-01
- Completion
- 2022-09-01
- First posted
- 2022-10-12
- Last updated
- 2023-12-06
Locations
1 site across 1 country: Germany
Source: ClinicalTrials.gov record NCT05576194. Inclusion in this directory is not an endorsement.