Trials / Recruiting
RecruitingNCT05538286
Transcranial Ultrasound Via Sonolucent Cranioplasty After Minimally Invasive Intracerebral Hemorrhage Evacuation
- Status
- Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 25 (estimated)
- Sponsor
- Icahn School of Medicine at Mount Sinai · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Postoperative rebleeding is a major limitation of surgical evacuation for intracerebral hemorrhage (ICH). While computed tomography (CT) is the standard of care for postoperative hematoma cavity monitoring, CT requires significant physical and financial costs. Studies have demonstrated varying degrees of efficacy when using transcranial ultrasound to measure ICH volume. Recently, synthetic implants for cranioplasty have been shown to be safe and sonolucent. This study aims to evaluate the ability of transcranial ultrasound with sonolucent cranioplasty (TUSC) to detect and quantify bleeding in postoperative ICH patients.
Detailed description
Intracerebral hemorrhage (ICH) accounts for over 2 million strokes annually. ICH is the most devastating subtype of stroke, with a 1-year mortality rate of up to 50% and a 6-month survivor disability rate of up to 88%. Large-scale multicenter trials including STICH, STICH II, and MISTIE III demonstrated that surgical evacuation did not appear to improve long term functional outcome. Smaller studies and sub-group analyses have suggested that some forms of minimally invasive ICH evacuation may benefit specific patients. Postoperative rebleeding after surgical evacuation of ICH occurs in 5-40% and remains a major limitation to the efficacy and widespread adoption of this treatment strategy. Therefore, rapid assessment, detection, and management of postoperative bleeding is critical to maximize functional recovery after surgical evacuation. The standard of care for postoperative hematoma cavity monitoring is computed tomography (CT). However, repeat CTs to assess patients with ICH incur health and financial cost including time and personnel to bring the patient to scan, risk of dislodging lines or drains, radiation dosing, and financial cost as well as others. Studies have demonstrated varying degrees of efficacy when using transcranial ultrasound to measure ICH volume. Recently, synthetic implants for cranioplasty have been shown to be safe and sonolucent. This study aims to evaluate the ability of transcranial ultrasound with sonolucent cranioplasty (TUSC) to detect and quantify bleeding in postoperative ICH patients. In this prospective study, postoperative ICH patients will undergo cranioplasty with a sonolucent polymethyl methacrylate implant and serial monitoring via TUSC. Whenever a CT is performed during business hours, TUSC will be performed within 2 hours by a neurointensivist trained in point-of-care transcranial ultrasound (TCUS). Imaging will be reviewed by two independent neuroimaging experts. Additional secondary outcomes will include occurrence of serious adverse events, detection of intraventricular hemorrhage, and cost of care when compared to CT. This work has the potential to significantly improve clinical management of ICH. This study will provide the safety and feasibility data necessary to guide future clinical research. ICH detection and volumetry are critical to patient care and prognostication. This point-of-care testing enables neurosurgeons to serially monitor patients to ensure that they receive timely, appropriate care.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | ClearFit implant | The ClearFit implant is an FDA cleared implant in regular use in the United States. The ClearFit implant and other PMMA cranioplasty implants manufactured by Longeviti have been reported to be safe and effective as cranial implants that permit transcranial ultrasound to be performed. The PMMA cranioplasty implant (Longeviti Neuro Solutions, Hunt Valley, MD) is clear, sonolucent, and was recently shown to be safe and effective in transcranial ultrasonography for bypass patency assessment. The ClearFit cranioplasty being used in this study is industry standard of care. |
| PROCEDURE | transcranial ultrasonography through sonolucent cranioplasty | The implantation of the ClearFit PMMA sonolucent implant permits TUSC to be performed at the bedside for patients in both the in-patient and outpatient settings. While the patient is an inpatient, the clinical or research teams will attempt to perform TUSC within 1 hour of neuroimaging if that neuroimaging is performed at a time when a trained ultrasound operator is present. |
Timeline
- Start date
- 2022-09-23
- Primary completion
- 2025-09-01
- Completion
- 2025-09-01
- First posted
- 2022-09-13
- Last updated
- 2025-02-06
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT05538286. Inclusion in this directory is not an endorsement.