Trials / Recruiting
RecruitingNCT05530408
Quantitative Pulmonary Imaging Registry & Biorepository
- Status
- Recruiting
- Phase
- —
- Study type
- Observational
- Enrollment
- 100 (estimated)
- Sponsor
- University of Kansas Medical Center · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Accepted
Summary
The goal of this project is to establish a registry and biorepository of images and biological samples from subjects undergoing novel pulmonary imaging methods to be used for future research aimed toward identifying clinical applications of imaging methods and toward understanding the physiological significance of imaging biomarkers. This registry and biorepository will accelerate the development of these imaging techniques and may lead toward future clinical adoption of quantitative pulmonary imaging.
Detailed description
Imaging is increasingly used for the non-invasive assessment of pulmonary health. Alongside this increased usage, there is enhanced interest in quantitative imaging methods that provide robust, repeatable, and objective measures of lung structure and function. At the forefront of this effort is quantitative computed tomography (qCT). CT imaging is the gold standard for high-resolution imaging of pulmonary structure, and the underlying physics of CT imaging is highly amenable to quantitative analysis. In addition to qCT, MRI is garnering increased interest as a modality for pulmonary imaging. Like CT, MRI is non-invasive, and it has the additional advantage of being ionizing radiation-free, making it more suitable for repeat imaging and for use in pediatric patients. Traditionally, MRI was not often used for lung imaging due to several difficulties regarding the acquisition of quality images in the lungs. However, recent advances to pulmonary MRI methods have enabled the acquisition of high-quality images of pulmonary structure and function. These advances include the use of ultra-short and zero echo time (UTE and ZTE, respectively) MRI methods, as well as the use of gaseous contrast agents such as hyperpolarized 129Xe. Despite these advances in qCT and MRI methods, the clinical applications for these imaging techniques are often unclear. Moreover, as new techniques, many of the imaging biomarkers in use have been independently developed by multiple sites and thus require standardization. As such, there is an urgent need both to standardize imaging/analysis techniques and to determine optimal clinical applications for these novel quantitative imaging methods.
Conditions
Timeline
- Start date
- 2022-05-24
- Primary completion
- 2027-12-31
- Completion
- 2028-05-31
- First posted
- 2022-09-07
- Last updated
- 2025-04-02
Locations
1 site across 1 country: United States
Source: ClinicalTrials.gov record NCT05530408. Inclusion in this directory is not an endorsement.