Trials / Completed
CompletedNCT05510869
Evaluation of the Impact of Corneal Width on Surgically Induced Astigmatism (SIA) and Functional Results After Bimanual 1.4 mm Microincision Cataract Surgery (B-MICS), Coaxial 1.8 mm MICS (C-MICS) and 2.4 mm Small Incision Cataract Surgery (C-SICS).
Comparison of Surgically Induced Astigmatism After Microincision Cataract Surgery (B-MICS 1.4 mm and C-MICS 1.8 mm) and C- SICS 2.4 mm
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 90 (actual)
- Sponsor
- Medical University of Lodz · Academic / Other
- Sex
- All
- Age
- 35 Years – 87 Years
- Healthy volunteers
- Not accepted
Summary
The aim of the study is to compare functional results and complications of 3 methods of cataract phacoemulsification: bimanual 1.4 mm cataract surgery (B-MICS), coaxial 1.8 mm cataract surgery (C-MICS) and coaxial 2.4 mm small incision cataract surgery.
Detailed description
Reduction of the width of the corneal incision was one the main changes taking place in cataract surgery in recent years. The common use of foldable intraocular lenses (IOLs) and technological development of phaco machines allowed to reduce clear corneal incision below 3 mm. Term of Microincision Cataract Surgery (MICS) understood as cataract phacoemulsification performed with the incision width below 2 mm was defined by professor Alio in 2003. However, despite various modifications introduced in recent years, phacoemulsification still causes damage of the tissues that results in surgically induced astigmatism. Two MICS techniques have been developed: bimanual microincision cataract surgery (B-MICS) and coaxial microincision cataract surgery (C-MICS). In the bimanual technique cataract phacoemulsification can be performed through the main incision 1.4 mm wide due to the usage of sleeveless phaco tip (without irrigation) and irrigation chopper. The advantage of separation the irrigation from aspiration is improvement of liquid dynamics in the anterior chamber. Moreover, due to the usage of the irrigation chopper, in B-MICS it is possible to lower the mean ultrasound energy. In coaxial technique MICS phacoemulsification is performed through the incision 1.8 mm wide with usage of phaco tip with a silicon irrigation sleeve. The aim of the study is to compare functional results and complications of 3 methods of cataract phacoemulsification: bimanual 1.4 mm cataract surgery (B-MICS), coaxial 1.8 mm cataract surgery (C-MICS) and coaxial 2.4 mm small incision cataract surgery. Moreover, this study aimed to evaluate the impact of corneal width on best corrected visual acuity (uncorrected and corrected), surgically induced astigmatism, endothelial cell loss, intraocular pressure, anterior segment of the eye and central retinal thickness.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Bimanual 1.4 mm microincision cataract surgery (B-MICS) with IOL implantation in a "wound-assisted" technique. In bimanual MICS group a self-sealing 1.4 mm wide incision was created supratemporally | microincision cataract surgery (phacoemulsification) with implantation of a foldable, acrylic, hydrophilic IOL Incise® MJ14, Bausch \& Lomb |
| PROCEDURE | Coaxial 1.8 mm microincision cataract surgery (C-MICS) with IOL implantation with an injector through the 1.8 mm wide incision created temporally. | microincision cataract surgery (phacoemulsification) with implantation of a foldable, acrylic, hydrophilic IOL Incise® MJ14, Bausch \& Lomb |
| PROCEDURE | Coaxial 2.4 mm small incision cataract surgery (C-SICS) with IOL implantation with an injector through the 2.4 mm wide incision located temporally. | small incision cataract surgery (phacoemulsification) with implantation of a foldable, acrylic, hydrophilic IOL Incise® MJ14, Bausch \& Lomb |
Timeline
- Start date
- 2016-01-01
- Primary completion
- 2019-01-01
- Completion
- 2019-05-01
- First posted
- 2022-08-22
- Last updated
- 2022-08-22
Source: ClinicalTrials.gov record NCT05510869. Inclusion in this directory is not an endorsement.