Clinical Trials Directory

Trials / Unknown

UnknownNCT05497128

Standard Cut Rate 27-Gauge System Versus Ultrahigh-Speed 27-Gauge System in Macular Surgery

Standard Cut Rate 27-Gauge System Versus Ultrahigh-Speed 27-Gauge System in Macular Surgery : A Randomized Controlled Trial

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
66 (estimated)
Sponsor
Seoul National University Bundang Hospital · Academic / Other
Sex
All
Age
19 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to compare the efficiency and safety of ultrahigh-speed cut rate 27-gauge system (27+®GA HYPERVIT® Vitrectomy Probe (Alcon Laboratories, Fort Worth, TX, USA)) and standard cut rate 27-gauge vitrectomy system (27+®GA Advanced ULTRAVIT® Vitrectomy Probe (Alcon Laboratories, Fort Worth, TX, USA)).

Detailed description

During the last few decades, there have been dramatic changes in vitreoretinal surgery field with improvements in the performance of surgical retina equipment. As the innovation trend has been moving toward the smaller instrument calibers, the 27-gauge vitrectomy system has been developed. However, the vitrectomy system with the smaller calibers have limitations such as reduced instrument rigidity, limited availability of instrumentation, and decreased flow rate. To overcome these limitations, active developments have been ongoing to increase vitreous cutting speed, enlargement of the cutting port size, and enlargement of inner shaft to enable higher flow rates. Especially, the ultrahigh-speed cutter with improved cutting speed has the advantage of enabling safer vitrectomy because the faster cutting speed reduces retinal movement and minimizes the risk of iatrogenic retinal breaks. However, ultrahigh-speed cutting has a limitation in that it can reduce the flow rate through the vitreous cutter as it affects the duty cycle (percentage of time the cutter port is open relative to the complete cutting cycle). Therefore, the duty cycle of ultrahigh-speed cutter has also been improved so as not to delay the time for vitrectomy. The investigators would like to evaluate the efficiency and safety of vitrectomy using a recently released ultra high-speed cut rate 27-gauge system (27+®GA HYPERVIT® Vitrectomy Probe (Alcon Laboratories, Fort Worth, TX, USA)) and a standard cut rate 27-gauge system (27+®GA Advanced ULTRAVIT® Vitrectomy Probe (Alcon Laboratories, Fort Worth, TX, USA)) by comparing the duration of vitrectomy and the rate of complications.

Conditions

Interventions

TypeNameDescription
DEVICEUltrahigh-speed cut rate 27-gauge systemThe ultrahigh-speed cut rate 27-gauge system (27+®GA HYPERVIT® Vitrectomy Probe (Alcon Laboratories, Fort Worth, TX, USA))
DEVICEStandard cut rate 27-gauge systemThe current standard cut rate 27-gauge vitrectomy system (27+®GA Advanced ULTRAVIT® Vitrectomy Probe (Alcon Laboratories, Fort Worth, TX, USA))

Timeline

Start date
2022-09-01
Primary completion
2023-08-01
Completion
2023-08-01
First posted
2022-08-11
Last updated
2022-08-15

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT05497128. Inclusion in this directory is not an endorsement.