Cough Assist Device in Mechanically Ventilated Patients

Role of Cough Assist Device in Mechanically Ventilated Patients in Respiratory Intensive Care Unit : Assiut University Experience

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
200 (estimated)
Sponsor
Assiut University · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Aspiration of respiratory secretions is a frequently needed procedure in intubated patients . Cough is an important defence mechanism to clear mucus from the upper and lower airways . The presence of an endotracheal tube impairs the ability to cough.There are a number of techniques to mobilise sputum and optimise airway clearance for invasively ventilated patients. Endotracheal suctioning is the most common intervention used to remove retained airway secretions from within the endotracheal tube, trachea and upper airways .Mechanical insufflation-exsufflation (MI-E) aids sputum clearance from upper and lower airways. This technique augments inspiratory and expiratory flows to improve sputum mobilisation, through the application of rapidly alternating positive and negative pressure, which approximates a normal cough

Detailed description

Critically ill patients under invasive ventilation are at risk for sputum retention . Aspiration of respiratory secretions is a frequently needed procedure in intubated patients . Cough is an important defence mechanism to clear mucus from the upper and lower airways . The presence of an endotracheal tube impairs the ability to cough. This prevents the enhancement of cough velocity . Furthermore, critically ill patients frequently have an impaired or no cough reflex due to depressed levels of consciousness, sedation, muscle weakness or muscle paralysis. Sputum retention, resulting from an inability to cough effectively, is one cause of extubation failure which in turn is associated with increased mortality. There are a number of techniques to mobilise sputum and optimise airway clearance for invasively ventilated patients. Endotracheal suctioning is the most common intervention used to remove retained airway secretions from within the endotracheal tube, trachea and upper airways . Endotracheal suctioning though is not effective for clearing secretions from the lower airways . New technologies and advanced methods have been developed to increase the effectiveness of mucus clearance in patients with acute respiratory failure, including mechanical insufflation-exsufflation devices. This technique has been described as an effective aid for mucus clearance in patients with chronic muscle weakness or neuromuscular disease. Mechanical insufflation-exsufflation (MI-E) aids sputum clearance from upper and lower airways. This technique augments inspiratory and expiratory flows to improve sputum mobilisation, through the application of rapidly alternating positive and negative pressure, which approximates a normal cough .

Conditions

Interventions

TypeNameDescription
DEVICEConventional tracheal suctioningGroup 1 allocated to conventional tracheal suctioning,all patiemts will be followed up until discharge from ICU or death Tracheal suctioning will be performed following the American Association for Respiratory Care recommendations.
DEVICEMechanical insufflation/exsufflationGroup 2 will be allocated to mechanical insufflation-exsufflation which will be performed with the which will be applied 5 times in 5cough cycles in automatic mode, with insufflation and exsufflation pressures of + 40/-40 cmH2O, respectively. The duration of each phase was 3 s, without pause. Hyperoxygenation (100% O2) will be performed for 1 min before applying each technique and a 20 s interval will be allowed between repetitions.

Timeline

Start date
2022-08-01
Primary completion
2023-07-30
Completion
2023-08-01
First posted
2022-07-29
Last updated
2022-07-29