Trials / Unknown
UnknownNCT05480137
OCT Evaluates the Effects of CTEPH Treated by Scoring Balloon
The Efficacy of Scoring Balloon Angioplasty in the Treatment of Chronic Thromboembolic Pulmonary Hypertension Based on Optical Coherence Tomography:A Single-center Randomized Controlled
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 46 (estimated)
- Sponsor
- First Affiliated Hospital of Chongqing Medical University · Academic / Other
- Sex
- All
- Age
- 18 Years – 80 Years
- Healthy volunteers
- Not accepted
Summary
Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease of obstructive pulmonary artery remodelling as a consequence of major vessel thromboembolism. The diagnosis of CTEPH is based on findings obtained after at least 3 months of effective anticoagulation in order to discriminate this condition from subacute PE. These findings are mean pulmonary artery pressure ≥25mmHg with pulmonary artery wedge pressure ≤15 mmHg, mismatched perfusion defects on lung scan and specific diagnostic signs for CTEPH seen by multidetector CT angiography, MR imaging or conventional pulmonary cineangiography, such as ring-like stenoses, webs/slits and chronic total occlusions (pouch lesions or tapered lesions). Balloon pulmonary angioplasty (BPA) is a type of effective treatment for CTEPH. Plain balloon is usually used in BPA surgery,however,the efficacy and safety of NSE scoring balloon in BPA is not clear. Optical coherence tomography(OCT)as a good assessment methods has been reported. Our study aims to explore the efficacy and safty of NSE scoring balloon based on OCT in BPA .
Detailed description
After right heart catheterization,BPA procedures are performed via femoral vein approach. 8-Fr sheath is inserted into the vein and 6-Fr guiding cathater was advanced to the main pulmonary artery through the 8-Fr guiding catheter using a 0.035-inch wire. We select a branch of the pulmonary artery by a 6-Fr guiding catheter (JR4.0). Pulmonary angiography is performed manually using half contrast medium diluted with saline. A 0.014-inch guidewire (Sion) is crossed under the pulmonary angiography, and OCT (Fig.1: Types of lesions) is used for the detection of Lumen diameter (mm), Intimal thickness (mm), Intimal area (mm2), Intimal thickness/lumen diameter, Intimal area/lumen area, which are defined as short diameter assessed by OCT. The balloon size, the expansion pressure and the choice of scoring balloon or plain balloon angioplasty are at the discretion of the operator. Balloon-to-vessel (B/V) ratio is defined as the balloon diameter divided by vessel diameter assessed with OCT (1:0.7-1). Pulmonary arteries with an inner diameter of less than 4mm detected by OCT were selected for BPA performance. Scoring balloon and plain balloon are used in half of pulmonary lesions respectively., use the Plain balloon was used to predilate, If the vascular Lesion is a completely occlusive or the scoring balloon cannot pass through vessels.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | NSE scoring balloon and plain balloon angioplasty | Using NSE scoring balloon or plain balloon in BPA surgery. |
Timeline
- Start date
- 2020-08-30
- Primary completion
- 2022-08-31
- Completion
- 2023-08-31
- First posted
- 2022-07-29
- Last updated
- 2022-07-29
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT05480137. Inclusion in this directory is not an endorsement.