Clinical Trials Directory

Trials / Completed

CompletedNCT05464446

Examination of Lower Urinary System Symptoms With Duchenne Muscular Dystrophy

Examination of Lower Urinary System Symptoms and Related Factors in Children With Duchenne Muscular Dystrophy

Status
Completed
Phase
Study type
Observational
Enrollment
45 (actual)
Sponsor
Lokman Hekim University · Other Government
Sex
Male
Age
5 Years – 18 Years
Healthy volunteers
Not accepted

Summary

The aim of this study is to examine the prevalence of lower urinary tract symptoms (LUTS) in children with Duchenne Muscular Dystrophy (DMD) and the relationship between functional level, posture, muscle strength, pelvic floor muscle control, participation in activities of daily living, and quality of life that may be associated with these symptoms. Forty-five children with DMD between the ages of 5-18 (Age: 9.00±3.32 years, Weight: 31,10±12,59 kg, Height: 125,87±18,46 cm) and their families were included in the study. LUTS was assessed with Dysfunctional Voiding And Incontinence Scoring System, functional level with Brooke Upper Extremity Functional Classification and Vignos Scale, posture with the New York Posture Assessment Questionnaire, Baseline Bubble Inclinometer (10602, Fabrication Enterprises Inc. New York, USA) and Baseline Digital Inclinometer (12-1057, Fabrication Enterprises Inc, New York, USA), participation in activities of daily living was assessed with the Barthel Index and quality of life was assessed with the Pediatric Quality of Life Inventory 3.0 Neuromuscular Module. Also, using the Hoggan microFET2 (Hoggan Scientific, LLC, Salt Lake City UT, USA) device, hip flexors, quadriceps femoris muscles, shoulder flexors, elbow extensors, elbow flexors, trunk extensors and flexors were evaluated in terms of muscle strength. Evaluations were made once, and the associated factors were compared in the group with and without LUTS, and the relationship between the factors and the severity of LUTS was examined.

Conditions

Interventions

TypeNameDescription
DEVICEBaseline Bubble Inclinometer, Baseline Digital İnclinometer and Hoggan microFET2 devicesBubble inclinometer was used to measure lumbar lordosis angle, Digital inclinometer was used to measure pelvic inclination angle and Hoggan microFET2 was used for muscle strength measurement.

Timeline

Start date
2021-10-01
Primary completion
2022-06-01
Completion
2022-06-20
First posted
2022-07-19
Last updated
2022-07-19

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT05464446. Inclusion in this directory is not an endorsement.