Clinical Trials Directory

Trials / Unknown

UnknownNCT05462691

"Suture of the Tuberosities in Inverted Prostheses" Implanted for Acute Fractures of the Proximal Humerus?.

"It is Necessary to Suture the Tuberosities in Inverted Prostheses Implanted for Acute Fractures of the Proximal Humerus?. Prospective Randomized Study

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
90 (estimated)
Sponsor
Hospital del Mar · Academic / Other
Sex
All
Age
65 Years – 85 Years
Healthy volunteers
Not accepted

Summary

Complex fractures of the proximal humerus in elderly patients constitute a growing problem. Osteoporosis linked to these fractures prevents osteosynthesis correctly, so that if the offset between the fragments is large, it is necessary to implant a prosthesis. Inverted prostheses, normally used for the treatment of osteoarthritis with absence of the rotator cuff, have become the treatment of choice in these fractures obtaining very favorable results. Traditionally, once the prosthesis is implanted, they are sutured the tuberosities with the rotator cuff tendons to the prosthesis. This gesture is supposed to will improve patient function. However, this prosthesis was originally designed for use in patients without a rotator cuff, so the need for this suture, which lengthens surgical time and requires an increase in the number of sutures, which can potentially increase the risk of infection. With the results of this study, it would be possible to reduce the surgical time, the number of inert materials implanted, and potentially the risk of infection.

Detailed description

Complex fractures of the proximal humerus in elderly patients constitute a growing problem. Osteoporosis linked to these fractures prevents osteosynthesis correctly, so that if the offset between the fragments is large, it is necessary to implant a prosthesis. Inverted prostheses, normally used for the treatment of osteoarthritis with absence of the rotator cuff, have become the treatment of choice in these fractures obtaining very favorable results. Traditionally, once the prosthesis is implanted, they are sutured the tuberosities with the rotator cuff tendons to the prosthesis. This gesture is supposed to will improve patient function. However, this prosthesis was originally designed for use in patients without a rotator cuff, so the need for this suture, which lengthens surgical time and requires an increase in the number of sutures, which can potentially increase the risk of infection. With the results of this study, it would be possible to reduce the surgical time, the number of inert materials implanted, and potentially the risk of infection. Primary objective: To determine if there are differences in the perception of quality of life measured by through the Simple Shoulder Test scale, among the patients in whom sutured the tuberosities and patients who have had the tuberosities excised tuberosities. Secondary objectives: To determine if there are differences between the patients in whom suturing has been the tuberosities and patients who have had their tuberosities excised about: * SPADI quality of life test. * Constant functional test. * number of prosthetic dislocations * Percentage of scapular notch development measured according to the Sirveaux scale. * Number of dislocations. * number of infections. * number of revision surgeries.

Conditions

Interventions

TypeNameDescription
PROCEDUREtuberosity sutureto suture or not suture the tuberosities in reverse shoulder arthroplasty because of a proximal humeral fracture

Timeline

Start date
2022-09-01
Primary completion
2023-09-01
Completion
2025-09-01
First posted
2022-07-18
Last updated
2022-07-18

Source: ClinicalTrials.gov record NCT05462691. Inclusion in this directory is not an endorsement.