Valve Hemodynamic Optimization Based on Doppler-Echocardiography vs Catheterization Measurements Following ViV TAVR
Valve Hemodynamic Optimization Based on Doppler-Echocardiography Versus Catheterization Measurements Following Valve-in-Valve TAVR: A Prospective Randomized Trial
- Status
- Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 310 (estimated)
- Sponsor
- Institut universitaire de cardiologie et de pneumologie de Québec, University Laval · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Data on valve performance following ViV-TAVR has usually been obtained with the use of Doppler-echocardiography. However, some reports have shown significant discordances in the evaluation of mean transvalvular gradient between echocardiography and catheterization, with an overestimation of the real gradient with echo (vs. cath) in most cases. Thus, the incidence of procedural-device failure may be lower than that reported in the ViV-TAVR literature,
Detailed description
This is a prospective, multicenter, randomized, single-blinded design trial including patients with surgical aortic bioprosthetic dysfunction in the presence of a stented surgical bioprosthesis with a labeled size ≤25 mm. Following the Heart Team's decision to proceed with a ViV-TAVR procedure with the SAPIEN 3 ULTRA valve (or its subsequent iterations), patients will be randomized to valve hemodynamic optimization according to Doppler-echocardiography versus cardiac catheterization parameters.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Doppler-echocardiography | The TAVR (valve-in-valve) procedure will be performed with the SAPIEN 3 Ultra valve, with valve sizing according to current manufacturer recommendations. Following valve implantation, further intervention will be based on Doppler-echocardiographic measurements. Balloon post-dilation with a non-compliant balloon will be performed in the presence of a residual mean gradient ≥20 mmHg as assessed by Doppler-echocardiography. |
| PROCEDURE | Invasive hemodynamic measurements | The TAVR (valve-in-valve) procedure will be performed with the SAPIEN 3 Ultra valve, with valve sizing according to current manufacturer recommendations. Following valve implantation, further interventions will be based on invasive hemodynamic measurements (with simultaneous aortic and ventricular pressure recording). Balloon post-dilation will be performed with a non-compliant balloon in the presence of a mean residual gradient ≥20 mmHg as assessed by hemodynamic measurements. |
Timeline
- Start date
- 2023-01-11
- Primary completion
- 2027-09-01
- Completion
- 2029-09-01
- First posted
- 2022-07-14
- Last updated
- 2026-03-24
Locations
7 sites across 2 countries: United States, Canada