Trials / Completed
CompletedNCT05443919
A Clinical Trial to Evaluate the Efficacy and Safety of TwiFlow-System for Acute Pulmonary Embolism
An Exploratory Study to Evaluate the Safety and Efficacy of a Novel Transcatheter Pulmonary Thrombectomy System Which Named 'TwiFlow' for Acute Pulmonary Embolism
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 13 (actual)
- Sponsor
- Morningside (Nantong) Medical Co.,Ltd · Academic / Other
- Sex
- All
- Age
- 18 Years – 75 Years
- Healthy volunteers
- Not accepted
Summary
For a prospective, single-arm clinical study, this study plans to recruit patients with acute pulmonary intravascular embolization, use production of transcatheter pulmonary artery bolt system which named 'TwiFlow-Thrombectomy Catheter System' developed by the MorningSide (NanTong) medical device Co., LTD. on pulmonary artery interventional therapy, for evaluating the efficacy and safety of this novel system in the treatment of patients with pulmonary intravascular embolization disease.
Detailed description
As a prospective, single-arm clinical study, the investigators plan to evaluate the new production's efficacy and safety which named 'TwiFlow-Thrombectomy Catheter System'. This study will be carried out in Xiamen Cardiovascular Hospital, Xiamen University. A total of 3 subjects are planned to be enrolled. After screening, all subjects will be treated with transcatheter pulmonary artery thrombectomy system, and clinical follow-up will be conducted at 48 hours, 14 days and 30 days after surgery. Right Ventricular/Left Ventricular decline from baseline to 48 hours after surgery and the incidence of major adverse events (MAE) within 48 hours after surgery were used as primary endpoints. In instrument performance evaluation, the success rate of surgery, postoperative immediate target lesion embolus removal efficiency, pulmonary artery pressure changes before and after operation value, values of arterial oxygen partial pressure changes before and after operation, death rates related to the equipment in 48 hours after surgery, incident rate of bleeding in 48 hours after operation, postoperative clinical deterioration rate in 48 hours after surgery, postoperative pulmonary vascular injury incidence in 48 hours after surgery, the incidence of heart damage injury in 48 hours after surgery, all-cause death rate in 30 days after surgery, and symptomatic Pulmonary Embolization recurrence rate in 30 days after surgery were secondary endpoints.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | TwiFlow-Thrombectomy Catheter System | Patients with acute pulmonary embolism and meeting the conditions of this clinical trial will accept the pulmonary embolism removal operation by the novel device named 'TwiFlow-Thrombectomy Catheter System'. |
Timeline
- Start date
- 2022-09-01
- Primary completion
- 2022-12-10
- Completion
- 2023-01-10
- First posted
- 2022-07-05
- Last updated
- 2023-05-15
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT05443919. Inclusion in this directory is not an endorsement.