Clinical Trials Directory

Trials / Completed

CompletedNCT05419258

Feasibility and Evaluation Study of the UPLUG Hemodialysis Connection Device

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
15 (actual)
Sponsor
University Hospital, Caen · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The new Uplug° technology, interface between the end of the hemodialysis catheter and the dialysis circuit, makes it possible to limit direct access to the hemodialysis catheter during connections and disconnections. Aim: The investigators propose a feasibility study, in order to study the new Uplug° technology in real conditions of use. Material and methods: This study aim to include 15 hemodialysis patients in a center on a tunneled permanent central venous hemodialysis catheter. The Uplug° technology will be placed at the end of each patient's hemodialysis catheter for a period of one month. Hypothesis tested: The main endpoint is the proportion of hemodialysis sessions performed successfully with this technology, respecting the usual dialysis prescription.

Detailed description

The incidence and prevalence of chronic insufficiency have been growing for several years. Increasingly older patients are treated with chronic hemodialysis. The vascular access of choice remains the arteriovenous fistula and the proportion of hemodialysis patients on the permanent central venous hemodialysis catheter varies from 20 to 35% in dialysis centres. The new Uplug° technology, interface between the end of the hemodialysis catheter and the dialysis circuit, makes it possible to limit direct access to the hemodialysis catheter during connections and disconnections. Aim: The investigators propose a feasibility study, in order to study the new Uplug° technology in real conditions of use. Material and methods: This study aim to include 15 hemodialysis patients in a center on a tunneled permanent central venous hemodialysis catheter. The inclusion period is three months. The follow-up time for each participant is 6 weeks. Patients with a tunneled permanent central venous hemodialysis catheter and performing dialysis sessions with a flow rate ≥ 300 ml/min may be included. The Uplug° technology will be placed at the end of each patient's hemodialysis catheter for a period of one month. Hypothesis tested: The main endpoint is the proportion of hemodialysis sessions performed successfully with this technology, respecting the usual dialysis prescription. The secondary objectives are the infectious risk, the defects of the experimental device and the hemodialysis catheter or their implementation, the satisfaction of the nursing staff and the patient, the reduction in the number of manipulations and the effective time of these manipulations.

Conditions

Interventions

TypeNameDescription
DEVICEUPLUG Hemodialysis Connection Deviceuse of the device UPLUG during 1 month

Timeline

Start date
2022-05-06
Primary completion
2023-10-30
Completion
2023-10-30
First posted
2022-06-15
Last updated
2024-02-13

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT05419258. Inclusion in this directory is not an endorsement.