Trials / Completed
CompletedNCT05385952
GATT-Patch Versus TachoSil in Liver Surgery
A Prospective, Multicenter, Randomized Clinical Investigation Evaluating the Safety and Efficacy of GATT-Patch Versus TachoSil for Hemostasis During Open Liver Surgery
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 132 (actual)
- Sponsor
- GATT Technologies BV · Industry
- Sex
- All
- Age
- 22 Years
- Healthy volunteers
- Not accepted
Summary
This is a pre-market, prospective, randomized (2:1), multicenter, multi-national pivotal clinical investigation. The purpose of this investigation is to determine the clinical safety and performance of GATT-Patch as compared with TachoSil for the management of minimal, mild, or moderate bleeding during elective open liver surgery.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | GATT-Patch (currently named ETHIZIA) | GATT-Patch (currently named ETHIZIA) is a sterile, flexible and resorbable hemostatic sealing patch. It presents as a blue, soft, flexible, porcine gelatin fiber-based carrier impregnated with an NHS-POx / NU-POx granulate. GATT-Patch measures 10 cm long by 5 cm wide. GATT-Patch is active and can be applied on both sides. Blue color is an aid to visualize GATT-Patch when applied onto a bleeding location. GATT-Patch is indicated for use as an adjunct to hemostasis in surgery for minimal, mild or moderate bleeding sites when control of bleeding by standard surgical techniques (such as suture, ligature or cautery) is ineffective or impractical. GATT-Patch is intended to be used for management of hemorrhage during surgeries on the liver. |
| DRUG | TachoSil | TachoSil is a topical fibrin sealant patch consisting of human fibrinogen and human thrombin coated onto an equine collagen sponge. TachoSil is a fibrin sealant patch indicated for use with manual compression in adult and pediatric patients as an adjunct to hemostasis in cardiovascular and hepatic surgery, when control of bleeding by standard surgical techniques (such as suture, ligature or cautery) is ineffective or impractical. |
Timeline
- Start date
- 2022-08-04
- Primary completion
- 2024-05-10
- Completion
- 2024-05-10
- First posted
- 2022-05-23
- Last updated
- 2026-03-04
- Results posted
- 2026-03-04
Locations
10 sites across 3 countries: United States, Germany, Netherlands
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT05385952. Inclusion in this directory is not an endorsement.