Trials / Completed
CompletedNCT05383768
Clinical Evaluation of Preheated and Repeated Preheated Versus Conventional Bulk Fill Resin Composite
Clinical Performance of Posterior Restorations of Bulk Fill Resin Composite Without Preheating Versus Repeated Preheating for One, Five and Ten Times: A Randomized Controlled Clinical Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 84 (actual)
- Sponsor
- Cairo University · Academic / Other
- Sex
- All
- Age
- 18 Years – 60 Years
- Healthy volunteers
- Accepted
Summary
A Randomized clinical trial to evaluate the clinical Performance of Posterior Restorations of Bulk Fill Resin Composite without Preheating Versus Repeated Preheating for One, Five and Ten times .The null hypothesis of this study is that there is no significant difference in clinical performance of the restoration during restoring posterior teeth when using bulk-fill without preheating and after repeated preheating for one , five and ten times in restoration of posterior teeth.
Detailed description
Dental resin composites are widely used for adhesive restorative procedures nowadays due to the significant improvement in their physical and mechanical properties. However, volumetric shrinkage is still an inherent drawback of the polymerization of the resin matrix . Preheating improves adaptation, polymerization shrinkage and degree of conversion without affect mechanical properties of resin composite restorations. In clinical situation, composite resin syringe is repeatedly used for restoration of several cavities and if preheating is applied, this syringe will undergo several heating cycles so repeated preheating effect on composite resin should be tested. Follow up Period will be 1 year , Evaluation will be done at 3,6,9 and 12 months .
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | preheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦C | Intervention 1: restoration with one-time preheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦C (Yang et al., 2020). Intervention 2: Restoration with five time preheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦C (Yang et al., 2020). Intervention 3: Restoration with ten time preheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦C (Yang et al., 2020). |
Timeline
- Start date
- 2022-03-01
- Primary completion
- 2023-04-01
- Completion
- 2023-04-01
- First posted
- 2022-05-20
- Last updated
- 2024-05-29
Locations
1 site across 1 country: Egypt
Source: ClinicalTrials.gov record NCT05383768. Inclusion in this directory is not an endorsement.