Clinical Trials Directory

Trials / Completed

CompletedNCT05383768

Clinical Evaluation of Preheated and Repeated Preheated Versus Conventional Bulk Fill Resin Composite

Clinical Performance of Posterior Restorations of Bulk Fill Resin Composite Without Preheating Versus Repeated Preheating for One, Five and Ten Times: A Randomized Controlled Clinical Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
84 (actual)
Sponsor
Cairo University · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Accepted

Summary

A Randomized clinical trial to evaluate the clinical Performance of Posterior Restorations of Bulk Fill Resin Composite without Preheating Versus Repeated Preheating for One, Five and Ten times .The null hypothesis of this study is that there is no significant difference in clinical performance of the restoration during restoring posterior teeth when using bulk-fill without preheating and after repeated preheating for one , five and ten times in restoration of posterior teeth.

Detailed description

Dental resin composites are widely used for adhesive restorative procedures nowadays due to the significant improvement in their physical and mechanical properties. However, volumetric shrinkage is still an inherent drawback of the polymerization of the resin matrix . Preheating improves adaptation, polymerization shrinkage and degree of conversion without affect mechanical properties of resin composite restorations. In clinical situation, composite resin syringe is repeatedly used for restoration of several cavities and if preheating is applied, this syringe will undergo several heating cycles so repeated preheating effect on composite resin should be tested. Follow up Period will be 1 year , Evaluation will be done at 3,6,9 and 12 months .

Conditions

Interventions

TypeNameDescription
OTHERpreheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦CIntervention 1: restoration with one-time preheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦C (Yang et al., 2020). Intervention 2: Restoration with five time preheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦C (Yang et al., 2020). Intervention 3: Restoration with ten time preheated conventional bulk-fill resin composite, X-tra fill (VOCO, GERMANY) at 68◦C (Yang et al., 2020).

Timeline

Start date
2022-03-01
Primary completion
2023-04-01
Completion
2023-04-01
First posted
2022-05-20
Last updated
2024-05-29

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT05383768. Inclusion in this directory is not an endorsement.