Trials / Completed
CompletedNCT05383417
No Post Intubation Laryngeal Symptoms
Endotracheal Tube Clip for Prevention of Post Intubation Laryngeal Symptoms
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 100 (actual)
- Sponsor
- University of California, San Diego · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Accepted
Summary
The purpose of the study is to test a novel endotracheal tube support device that reduces pressure of the tube on the voice box for prevention of post intubation laryngeal symptoms including sore throat, change in voice and trouble swallowing.
Detailed description
Single center randomized controlled trial with 100 subjects who will be intubated for already planned surgeries. The participants will be randomized into the control group or the clip group. The clip group will have a small clip (the endotracheal tube support device) placed on the endotracheal tube to reduce the pressure on the vocal cords and larynx. This endotracheal tube support device is made from a FDA approved biocompatible material. The control group subjects will undergo their planned procedure with no intervention during intubation. The clip group will undergo their planned procedure as normal but with the endotracheal tube support device placed on the endotracheal tube by the assigned anesthesia attending physician. The clip is placed once the tube is secured and the ventilator circuit is connected. While extubating the patient, the endotracheal tube will be removed with the clip attached and a picture of the tube will be taken to record the clip location. Before the planned procedure, the investigators will survey the participants to get a baseline for any pre-existing laryngeal symptoms. The same survey will be administered after the procedure when the participants are awake and alert just prior to discharge, 24 hours, 48 hours, and 1 week after the procedure. The survey will ask the participant to indicate "yes" or "no" for whether they are experiencing a sore throat, throat pain, oral pain, difficulty speaking, difficulty swallowing, changes in their voice, pain while speaking, and pain while swallowing. If they have indicated "yes" for any of the symptoms, the participants will also be asked to mark the severity on a visual analog scale from 1 to 10. Other data points will also be collected in this study that are related to the intubation and participant's airway. The investigators will record the total time of the procedure and the length of time the clip is placed on the endotracheal tube. For each participant in the clip group, the investigators will also record the time it takes to place the clip on the endotracheal tube. Each participant's airway will be evaluated, and the investigators will record the thyromental distance, Mallampati score, history of difficult intubation, and the size of the endotracheal tube used. Lastly, data from each participant's intubation will be collected including number of attempts before successful intubation, incidence of dental injury, incidence of lip injury, laryngeal view on Cormack-Lehane scale, and any noted trauma upon extubation. Lastly, the investigators will have the anesthesiologists recruited for the study fill out a modified National Aeronautics and Space Administration (NASA) Task Load Index (TLX) form to evaluate the end-user experience for the device.
Conditions
- Sore-throat
- Dysphonia
- Dysphagia
- Intubation Complication
- Anesthesia Intubation Complication
- Anesthesia Morbidity
- Anesthesia Complication
- Anesthesia; Adverse Effect
- Anesthesia; Reaction
- Throat Disorder
- Throat; Wound
- Throat Injury
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | EndoClip | Clip attached to mid portion of the endotracheal tube. |
Timeline
- Start date
- 2022-11-08
- Primary completion
- 2023-09-21
- Completion
- 2023-09-21
- First posted
- 2022-05-20
- Last updated
- 2025-09-10
- Results posted
- 2025-09-10
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT05383417. Inclusion in this directory is not an endorsement.