Clinical Trials Directory

Trials / Terminated

TerminatedNCT05299177

Feasibility of Automated Insulin Delivery With an Interoperable Algorithm Using an Alternative Insulin Pump

Status
Terminated
Phase
N/A
Study type
Interventional
Enrollment
1 (actual)
Sponsor
Imperial College London · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This clinical study assesses the feasibility of implementing the inControl automated insulin delivery algorithm with Dexcom continuous glucose monitoring and a compatible insulin pump in adults with type 1 diabetes. It additionally provides pilot efficacy outcomes for interoperable automated insulin delivery.

Detailed description

Self-management of type 1 diabetes is challenging, efforts to optimise time spent in the target range can result in hypo- and hyperglycaemia. Structured education, glucose monitoring and advances in insulin delivery can increase time in range and reduce exposure to extremes of glucose and recent data confirm that automated insulin delivery can enable further increases in time spent in the target range of 3.9 to 10mmol/L (70 - 180mg/dL). The inControl algorithm, developed by TypeZero technologies is embedded in the Tandem X2 insulin pump and operates with the Dexcom G6 continuous glucose sensor and transmitter in a CE-marked and commercially available system (known as Control-IQ). This system optimises time in range compared with sensor-augmented pump therapy, and the improvement was maintained when participants were further randomised to predictive low glucose suspend or automated insulin delivery. The United States Food and Drug Administration has defined interoperable standards for automated insulin delivery systems, including the iCGM designation for continuous glucose sensors, the interoperable automated glycaemic controller designation, and alternate controller enabled insulin pumps. However, while standards have been defined, to date, interoperability of automated insulin delivery components has not been demonstrated.

Conditions

Interventions

TypeNameDescription
DEVICEInControlAutomated insulin delivery system comprising continuous glucose sensor (Dexcom G6), controller (InControl embedded in smartphone app) and insulin pump (YpsoMed Ypsopump)

Timeline

Start date
2022-04-01
Primary completion
2025-08-31
Completion
2025-08-31
First posted
2022-03-28
Last updated
2025-09-03

Locations

1 site across 1 country: United Kingdom

Source: ClinicalTrials.gov record NCT05299177. Inclusion in this directory is not an endorsement.