Clinical Trials Directory

Trials / Recruiting

RecruitingNCT05287646

Quantifying Bone and Skin Movement in the Residual Limb of Individuals With Transtibial Amputation Using Dynamic Stereo X-Ray

Quantifying Bone and Skin Movement in the Residual Limb-Socket Interface of Individuals With Transtibial Amputation Using Dynamic Stereo X-Ray

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
21 (estimated)
Sponsor
VA Office of Research and Development · Federal
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Individuals with lower extremity amputation are often challenged by complications that arise from poor prosthetic fit, including movement of the residual limb in the socket, known as pistoning. Pistoning can lead to gait instability, skin problems, and pain. Different prosthetic suspension systems have been developed to decrease this motion, including elevated vacuum suspension, which utilizes a pump to draw air from the socket. However, scientific analyses to understand the movement between the limb and socket have yet to be performed with a high level of accuracy. This study will use a state-of-the art imaging technique, known as dynamic stereo x-ray, to quantify the 3D movement of the residual limb in the socket. It is hypothesized that dynamic stereo x-ray will be a sensitive method to measure differences in residual limb movement between 2 different socket suspension techniques: suction and elevated vacuum suspension. This information is critical for advancing prosthetic treatments to reduce secondary conditions and degenerative changes that result from poor prosthetic fit.

Detailed description

Individuals with lower extremity amputation (LEA) often experience relative motion between their residual limb and the prosthetic socket, such as vertical translation and axial rotation, which can cause inefficient dynamic load transmission from the distal prosthetic components to the residual limb. This can lead to significant secondary consequences, such as pain, gait deviations, and discomfort that limit mobility and autonomy. Assessments of the relative motion between the bone and the prosthetic socket have been performed, but there is little existing data on dynamic, in vivo residual limb-socket kinematics since most investigations have been performed using non-dynamic testing protocols, static measurements, or with unvalidated surface marker-based motion capture systems. Dynamic Stereo X-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and tissue/liner deformation inside a prosthetic socket during dynamic activities. There is a substantial gap in our understanding of the complex mechanics of the residual limb-socket interface during dynamic activities that limit the ability to improve prosthetic design. The goals for this project are to develop the analytical tools to quantify both the dynamic, in-vivo kinematics between the residual limb and socket, as well as the mechanism of residual tissue/liner deformation. In order to validate the sensitivity of this methodology to differences in socket suspension, 2 suspension systems will be evaluated: elevated vacuum and traditional suction. It is hypothesized that an efficient and highly accurate method to quantify the dynamic interaction between the residual limb and prosthetic socket will be sensitive enough to distinguish between different types of prosthetic socket suspension, which will further the biomechanical understanding of socket design. To do so, the investigators will address the following aims: (1) To optimize the DSX procedural setup for the accurate tracking of the prosthetic socket, skeletal kinematics, and tissue/liner deformation; (2) To quantify the relative motion between the residual tibia and the prosthetic socket during dynamic activities; and (3) To measure the deformation of the skin and liner in the prosthetic socket during dynamic activities. Twenty-one participants with transtibial amputation will be fit with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested at the DSX facility. DSX will be utilized to track skeletal and skin/liner motion under both suspension techniques during 3 dynamic activities: treadmill walking at self-selected speed, fast walking (10% faster), and a step-down movement. The performance of the two suspension techniques (active EV and traditional suction) will be tested by quantifying the 3D bone movement of the residual tibia with respect to the prosthetic socket and quantifying liner and soft tissue deformation at the socket-residuum interface. By using the analytical tools for a highly accurate, in-vivo assessment of residual limb-socket motion, vital foundational information can be provided to aid in the development of new methods and techniques to enhance prosthetic fit that have the potential to reduce secondary physical comorbidities and degenerative changes that result from complications of poor prosthetic load transmission.

Conditions

Interventions

TypeNameDescription
DEVICESuction Suspension FirstParticipants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system inactive (traditional suction). Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system active.
DEVICEElevated Vacuum Suspension FirstParticipants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system active. Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system inactive.

Timeline

Start date
2024-01-05
Primary completion
2027-02-28
Completion
2027-03-31
First posted
2022-03-18
Last updated
2026-03-12

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT05287646. Inclusion in this directory is not an endorsement.