Trials / Completed
CompletedNCT05282264
Acceptability of Hybrid Closed-loop Systems in Patients Living With Highly Unbalanced Type 1 Diabetes
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 66 (actual)
- Sponsor
- Centre Hospitalier Sud Francilien · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
While closed-loop insulin delivery (CLID) systems demonstrated safety and effectiveness in patients with unbalanced type 1 diabetes (T1D), no studies have included patients with highly and chronically unbalanced diabetes. The investigators conduct a retrospective, observational, and single-center study to evaluate the acceptability, safety, and efficacy of a CLID system in patients living with T1D (≥2 years) with a HbA1c\>11% in the past 12 months and a mean HbA1c \>10% over the past three years. Efficacy was assessed using continuous glucose monitoring parameters.
Detailed description
If hybrid closed-loop systems (HCLS) ("artificial pancreas") for automated insulin administration have demonstrated their great interest in patients living with moderately unbalanced type 1 diabetes (T1D) (HbA1c \< 8 .6% on average), no study has looked at their safety, acceptability and efficacy in patients living with highly and chronically unbalanced T1D (HbA1c \> 11%). These patients, often young, present more or less advanced microangiopathic complications (retinopathy, nephropathy, neuropathy, etc.) or are highly exposed to the appearance of these complications, the prevention of which, whether primary or secondary, involves obtaining a good glycemic balance over time. These patients "escape" the possibilities of current insulin therapy, whether by multiple insulin injections or by insulin pump, more or less coupled to a continuous glucose monitoring system. Automated insulin delivery systems could be a solution to achieve less catastrophic glycemic control in some of these patients. The investigators are proposing a pilot study aimed at evaluating acceptability, safety and effectiveness of a HCLS currently available in France (the SMARTGUARD™ MINIMED™ 780G or the Control-IQ) in patients followed in the diabetology department of the Centre Hospitalier Sud-Francilien (CHSF), living with highly unbalanced T1D (HbA1c \> 11%) in the context of usual follow-up.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | device | closed-loop insulin |
Timeline
- Start date
- 2022-04-01
- Primary completion
- 2023-07-15
- Completion
- 2023-12-11
- First posted
- 2022-03-16
- Last updated
- 2023-12-21
Locations
2 sites across 1 country: France
Source: ClinicalTrials.gov record NCT05282264. Inclusion in this directory is not an endorsement.