CompletedNCT05234099

Sensitivity and Reproducibility of 18F-fluorodeoxyglucose Positron Emission Tomography for Assessment of Respiratory Muscle Activity

Evaluation of the Sensitivity and Reproducibility of 18F-fluorodeoxyglucose Positron Emission Tomography Coupled With Magnetic Resonance Imaging for the Assessment of Respiratory Muscle Activity and Relationships With Multiparametric Respiratory Muscle Ultrasound

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
15 (actual)
Sponsor
Institut de Myologie, France · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

The assessment of respiratory muscle function is critical within both clinical and research settings. Tools for the assessment of respiratory muscle function are especially useful in diagnosing, phenotyping, understanding pathophysiology, and assessing treatment responses in patients with respiratory symptoms, including critically hill patients and patients with respiratory and/or neuromuscular diseases. Respiratory muscle function is most commonly assessed using flow (i.e. spirometry) and pressure measurements during spontaneous ventilation, voluntary respiratory efforts, or artificially evoked responses using magnetic or electrical stimulation. Some of these approaches may be limited within patients suffering from neuromuscular diseases. The study hypothesis is the 18F-FDG PET technology, heavily used for clinical oncology purposes (diagnostic, staging, response to treatment, prognosis), could be an interesting alternative to invasive measurement of the respiratory muscle activity. In addition, it may contribute to further validate metrics based on multiparametric ultrasound imaging.

Detailed description

The assessment of respiratory muscle function is critical within both clinical and research settings. Tools for the assessment of respiratory muscle function are especially useful in diagnosing, phenotyping, understanding pathophysiology, and assessing treatment responses in patients with respiratory symptoms, including critically hill patients and patients with respiratory and/or neuromuscular diseases. Respiratory muscle function is most commonly assessed using flow (i.e. spirometry) and pressure measurements during spontaneous ventilation, voluntary respiratory efforts, or artificially evoked responses using magnetic or electrical stimulation. Some of these approaches may be limited, for instance, when facial muscle weakness occurs and/or when glottis function is compromised, for example in patients with bulbar amyotrophic lateral sclerosis or myopathies. Consequently, widely used respiratory measures can be poor predictors of respiratory muscle alterations and this may contribute to affect clinical decisions such as the time when non-invasive ventilation should be initiated within the disease continuum. Positron emission tomography (PET) is a nuclear medicine procedure based on the measurement of positron emission from radiolabeled tracer molecules. These radiotracers allow biologic processes to be measured and whole-body images to be obtained which demonstrates sites of radiotracer accumulation. Fluorodeoxyglucose (18F-FDG) is a radiolabeled glucose molecule and is the most common radiotracer used in clinical practice. 18F-FDG PET is most frequently coupled with computed tomography but may also be coupled with magnetic resonance imaging (18F-FDG PET-MRI). 18F-FDG PET is heavily used for clinical oncology purposes (diagnostic, staging, response to treatment, prognosis). 18F-FDG PET also finds applications in other fields for detecting infections and inflammatory processes. 18F-FDG may also be used in muscles that are major user of glucose. 18F-FDG PET offers the opportunity to assess the patterns and work amount of multiple muscles simultaneously, providing a global view of the muscles involved in the realization of a motor task, as previously demonstrated in shoulder muscles. Ultrasound imaging (US) is attracting a growing interest for the assessment of respiratory muscle function, as it allows bedside and non-invasive assessments. Recently, new US techniques such as shear wave elastography (SWE) have shown promises for the assessment of respiratory muscle work. However, the ability of variables derived from respiratory muscle US to reflect increased muscle work remains unclear. Hence, building evidences supporting non-invasive US biomarkers for respiratory muscle function is necessary. 18F-FDG PET offers a unique opportunity to investigate patterns and work amount of the respiratory muscles. In a resting state, 18F-FDG uptake in the respiratory muscle is known to be small. However, and to the best of our knowledge, 18F-FDG uptake of the respiratory muscles at rest in healthy subjects has never been specifically reported. It is unclear whether 18F-FDG PET may be used to monitor changes in respiratory muscle activity within the disease continuum or in response to an intervention such as the initiation of non-invasive ventilation. The reproducibility of increase 18F-FDG uptake of the respiratory muscles induced remains to be assessed and is a prerequisite to determine its sensitivity to change. Moreover, the relationship between increase 18F-FDG uptake and respiratory muscle work as assessed using other methods (e.g. flow and pressure measurements, surface electromyography (sEMG)) and variables derived from multiparametric US remains to be determined. Since MRI does not use ionizing radiations, and because of very higher soft-tissue contrast capabilities, combining PET to MRI instead of CT is of better relevance for our PET muscular analyses purpose.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TEST18F-FDG Positron emission tomography - MRIAll the examinations will be performed in the supine position on the same integrated 3T PET-MRI scanner
DIAGNOSTIC_TESTMultiparametric ultrasound imagingAcquisitions of respiratory muscles (diaphragm, intercostal muscles) will be performed using two 6 MHz central frequency linear transducer (SL 10-2) driven by two identical ultrafast ultrasound devices.
DIAGNOSTIC_TESTSurface electromyographysEMG recordings will be performed in the left side on the sternocleidomastoid muscle, the intercostal parasternal muscle, and the external oblique muscle using pairs of 20-mm-diameter silver chloride surface electrodes.
DIAGNOSTIC_TESTTransdiaphragmatic preasure measurmementEsophageal and gastric pressures will be measured using 8-cm balloon-catheters.
DIAGNOSTIC_TESTMagnetic stimulation of the phrenic nervesIn order to quantify the contractile fatigue in diaphragm induced by the ventilatory task (described below), we will use bilateral anterior magnetic stimulation of the phrenic nerves using two Magstim 200 stimulator.
DIAGNOSTIC_TESTVentilation against inspiratory loadingA POWERbreathe KH2 device (POWERbreathe International Ltd) will be connected on the inspiratory side of the two-way valve. Level of inspiratory loading will be randomized in order to produce different amounts of muscle work in each subject.

Timeline

Start date
2022-05-05
Primary completion
2023-12-22
Completion
2023-12-22
First posted
2022-02-10
Last updated
2024-04-10

Locations

2 sites across 1 country: France