Clinical Trials Directory

Trials / Unknown

UnknownNCT05212441

ADJUNCTIVE EFFECT OF LIGHT EMITTING DIODE ON HAND GRIP STRENGTH IN BURN PATIENTS

ADJUNCTIVE EFFECT OF LIGHT EMITTING DIODE ON HAND GRIP STRENGTH IN BURN PATIENTS: A Randomized Controlled Trial

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
60 (actual)
Sponsor
October 6 University · Academic / Other
Sex
All
Age
20 Years – 35 Years
Healthy volunteers
Not accepted

Summary

This study will be done to evaluate effect of applying LED before hand exercise on hand grip strength. Sixty male patients with subacute partial thickness burn of hand will be randomly allocated into two equal groups of 30 patients. The following equipment and tools will be used Measurement equipments: * For total active motion of fingers (TAM): Goniometer. * For hand grip strength: Hand grip dynamometer. Therapeutic equipment: Light emitting diode therapy (LED) device.

Conditions

Interventions

TypeNameDescription
DEVICELight emitting diode therapy (LED therapy)The patient's forearm is positioned on table with palm facuing upward during the therapy. For LEDT, the center of the light spot located at approximately 50% of landmark line from the medial epicondyle to the styloid process of the ulna, which is the center belly of flexor digitorum superficialis. The subject's forearm maintained in the rest state without moving during the therapy. LED is performed before exercise.
BEHAVIORALPatient/family education program (Home program)Patients and their families will instructed to learn the anti contracture positioning/splinting, scar massage and exercises program, application of the custom garments and inserts, and functional training to perform them on their own at home. Written and illustrative instructions and reciprocal demonstration sessions will be provided to the children and their families to ensure successful acquisition and delivery of rehabilitation skills at home program. The therapist will be reported about compliance with the home program every couple of days
PROCEDUREPositioning & SplintingThe wrist joint is splinted at 30 hyperextension, the MCP joint in 90 of flexion, the IP joints in extension, and the thumb in abduction. The webs of fingers kept in abduction. The hands are elevated above the level of the heart to minimize post-burn edema. Splinting: Splints are tailored to help to maintain the functional or anti-contracture position of the injured body parts.The intervals for monitoring vary from once every hour to once every 4-6 hours, depending on types of splints and skin conditions. It is described as 10 hours on and two hours off. When the splint is taken off, active and/or passive ROM should be carried out.
OTHERTherapeutic Exercises1. Passive ROM (PROM). 2. Active ROM (AROM) \& Active-assistive ROM (AAROM): The exercise will focus on extending the wrist to 45 degrees, flexing the MCP joints to 90 degrees and keeping the IP joints in full extension, while maintaining a thumb web space. The exercises will performed in the following sequences; (1) MCP joints flexion and extension with the wrist in neutral or slight extension and the IP joints in neutral position. (2) IP joints flexion to only 30-40 degrees with the wrist stabilized in the neutral or slight extension, while the MCP joints held in full extension, (3) thumb and fingers abduction and adduction, and (4) thumb opposition (tip of the thumb to tip of the small finger). Each exercise was performed for 8-10 repetition, daily, for 6 days/week. 3. Stretching exercises: A low-load (low-intensity), long-duration stretch 4. Strengthening exercises: done in static mode initially and progress to dynamic strengthening using elastic bands.

Timeline

Start date
2022-02-25
Primary completion
2022-07-01
Completion
2022-07-10
First posted
2022-01-28
Last updated
2022-05-10

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT05212441. Inclusion in this directory is not an endorsement.