CompletedNCT05176860

Evaluation of Novel Cone-Beam CT for Guidance and Adaptation of Precision Radiotherapy

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
30 (actual)
Sponsor
Varian, a Siemens Healthineers Company · Industry
Sex
All
Age
19 Years
Healthy volunteers
Not accepted

Summary

This is a feasibility study investigating the image quality of a new, high-performance cone beam CT (CBCT) used for on-couch imaging during radiotherapy treatments.

Detailed description

This study focuses on potential benefits of a high performance cone beam CT (CBCT) image guidance system for improved precision in the delivery of radiotherapy. CBCT is currently used during radiation therapy to align the patient to their original treatment plan to increase the precision of radiation delivery. Current CBCT imaging technology requires approximately a minute to acquire an image. In order to acquire images with sufficient quality to allow accurate targeting, the patient may need to perform multiple breath hold maneuvers to "freeze" the motion of tumors that move with the breathing cycle (e.g. lung, liver, and breast tumors). The new high-performance CBCT can acquire an image in approximately 6 seconds, potentially enabling acquisition of images with a single breath hold. Improved motion compensation algorithms used in image reconstruction may allow acquisition of good quality images even while a patient is not holding their breath. The methodology for the subject's treatment setup, CT simulation, treatment planning, image guidance and treatment delivery will be determined by the subject's treatment team and is not specified by this study. Enrollment in the study may occur after treatment delivery has started but must be prior to the fifth fraction. Following completion of informed consent to participate in this study, high-performance CBCT imaging will be scheduled immediately before or after one of the subject's first five scheduled radiation treatment fractions. Two research CBCT images will be acquired, one with breath hold, the other with free breathing. With minimal disruption for participating patients, this study will enable a comparison of (i) the subject's treatment planning fan-beam CT and (ii) the conventional CBCT acquired on an existing treatment unit with (iii) the high-performance CBCT. Image quality of the high performance CBCT image data will thereby be compared to both a best-case standard (fan-beam) and the status-quo for on-couch imaging to isolate and identify improvements.

Conditions

Interventions

TypeNameDescription
DEVICECBCT ImagingTwo research CBCT images will be acquired per subject.

Timeline

Start date
2022-12-20
Primary completion
2023-07-30
Completion
2023-07-30
First posted
2022-01-04
Last updated
2023-09-06

Locations

1 site across 1 country: Canada

Regulatory

Source: ClinicalTrials.gov record NCT05176860. Inclusion in this directory is not an endorsement.

Evaluation of Novel Cone-Beam CT for Guidance and Adaptation of Precision Radiotherapy (NCT05176860) · Clinical Trials Directory