Clinical Trials Directory

Trials / Completed

CompletedNCT05151991

A Clinical Trial on the Failure Rates of Metallic and Ceramic Orthodontic Brackets

A 12-months Evaluation of the Failure Rates of Stainless Steel and Ceramic Brackets in Orthodontic Fixed Therapy: a Clinical Trial.

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
80 (actual)
Sponsor
University of Pavia · Academic / Other
Sex
All
Age
Healthy volunteers
Not accepted

Summary

The aim of this study is to assess if there are significant differences in the failure rate of stainless steel and ceramic brackets. For this study, patients will be enrolled and divided into two groups, according to the type of brackets (stainless steel or ceramic) used for orthodontic treatment. Failure rates will be recorded every month for 12 months and survival analysis will be performed, together with skeletal and space analysis.

Detailed description

This clinical trial aims to investigate if there are differences in the failure rates of stainless steel and ceramic orthodontic brackets. Patients willing to start orthodontic fixed therapy and recruited for the study will be asked to sign the informed consent. Parents will sign the consent for underage patients. After that, patients will be divided into two groups: * Group MET: stainless steel brackets will be bonded on the vestibular surfaces of teeth. * Group CER: ceramic brackets will be bonded on the vestibular surfaces of teeth. The following sequence of archwires will be adopted for the first six months: 0.012-in Niti, 0.014-in Niti, 0.016-in NiTi, 0.018 SS Australian, 0.020 SS Australian, 0.017X0.025-in NiTi, 0.019X0.025-in SS. The failure rates of the brackets will be recorded each month for 12 months. Each failed bracket will be recorded once. For each patient, pre-treatment lateral cephalometric radiograph and study models will be used to measure ANB angle, Wits, Skeletal Class, dento-alveolar discrepancy and Little Index at the beginning of the treatment. Bond failures will be recorded together with the archwire engaged at the moment of the failure. Sample size Sample size was calculated with the following assumptions: ability to detect a clinically relevant difference of 4.935% in the failure rates (primary outcome) of the two groups with an alfa = 0.05 and power = 80%. The assumptions were based on findings of a previous study with an expected value of 12.08% for the first group at the end of 12 months of therapy. Therefore, 800 brackets (40 patients) per group were required for the study. Statistical analysis Statistical analysis will be conducted with R software (R version 3.1.3, R Development Core Team, R Foundation for Statistical Computing, Wien, Austria). Fisher exact test will be performed to evaluate the differences between the failure rates of the two groups, between anterior and posterior sites and between upper and lower arches. Kaplan-Meier survival analysis of the bond failures will be performed among the 12 months of the study. Linear regressions will be calculated to assess the effects on bond failure of the skeletal and dental variables collected before the bonding procedure. Significance for all statistical tests will be predetermined at P\<0.05.

Conditions

Interventions

TypeNameDescription
OTHERFixed orthodontic treatment with stainless steel bracketsOrthophosphoric acid 37% acid (Gerhò Etchant gel 37%, Gerhò spa, Terlano, Italy) will be applied for 30 s for the etching of the vestibular surfaces of teeth. The, after rinsing and drying, a thin layer of Transbond XT Light Cure Adhesive Primer (3M Unitek, Monrovia, CA, USA) will be applied and then cured for 10 s with a LED unit. At last, Transbond XT Light Cure Adhesive Paste (3M Unitek) will be applied on the base of stainless steel brackets (Queen Series Low Profile Brackets MBT 0.022", Aestetika, Terni, TR, Italy); brackets will be applied on the vestibular surfaces of teeth with a light pressure and the extra paste will be removed. Curing will be performed with the LED unit at 2 mm distant from the enamel-bracket interface for 40 s, 10 s per each surface (mesial, distal, gingival and occlusal). The following sequence of archwires will be adopted for the first six months: 0.012-in Niti, 0.014-in Niti, 0.016-in NiTi, 0.018 SS, 0.020 SS, 0.017X0.025-in NiTi, 0.019X0.025-in SS.
OTHERFixed orthodontic treatment with ceramic bracketsOrthophosphoric acid 37% acid (Gerhò Etchant gel 37%, Gerhò spa, Terlano, Italy) will be applied for 30 s for the etching of the vestibular surfaces of teeth. The, after rinsing and drying, a thin layer of Transbond XT Light Cure Adhesive Primer (3M Unitek, Monrovia, CA, USA) will be applied and then cured for 10 s with a LED unit. At last, Transbond XT Light Cure Adhesive Paste (3M Unitek) will be applied on the base of ceramic brackets; brackets (Super Clear Series Brackets MBT 0.022", Aestetika, Terni, TR, Italy) will be applied on the vestibular surfaces of teeth with a light pressure and the extra paste is removed. Curing will be performed with the LED unit at 2 mm distant from the enamel-bracket interface for 40 s, 10 s per each surface (mesial, distal, gingival and occlusal). Then, the following sequence of archwires will be adopted for the first six months: 0.012-in Niti, 0.014-in Niti, 0.016-in NiTi, 0.018 SS, 0.020 SS, 0.017X0.025-in NiTi, 0.019X0.025-in SS

Timeline

Start date
2021-12-09
Primary completion
2023-05-04
Completion
2023-05-08
First posted
2021-12-09
Last updated
2024-01-17

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT05151991. Inclusion in this directory is not an endorsement.