Clinical Trials Directory

Trials / Terminated

TerminatedNCT05147584

Trans-abdominal Fetal Pulse Oximetry

Trans-abdominal Fetal Pulse Oximetry: PILOT 1

Status
Terminated
Phase
N/A
Study type
Interventional
Enrollment
31 (actual)
Sponsor
Raydiant Oximetry, Inc. · Industry
Sex
Female
Age
18 Years
Healthy volunteers
Accepted

Summary

The Raydiant Oximetry Sensing System (Lumerah) is a non-invasive fetal pulse oximeter that measures fetal arterial oxygen saturation using safe, non-invasive, transabdominal near-infrared spectroscopy. Lumerah is intended as an adjunct to cardiotocography by detecting decreases in fetal oxygenation.

Detailed description

Raydiant Oximetry, Inc. is developing a novel and non-invasive fetal pulse oximetry device to fundamentally improve how fetuses are monitored during labor. The Raydiant Oximetry Sensing System (Lumerah) is a fetal pulse oximeter that measures fetal arterial oxygen saturation using safe, non-invasive, transabdominal near-infrared spectroscopy. Lumerah performs its measurements without the requirement for transvaginal placement and its associated risks. Lumerah is intended as an adjunct to cardiotocography by detecting fetal oxygen deprivation which is both life-threatening to the fetus and can lead to the irreversibly debilitating consequences of newborn metabolic acidosis. The severe consequences associated with newborn metabolic acidosis and the lack of availability of an effective tool to support its early diagnosis led to the development of Lumerah. In this study, women in labor will be simultaneously monitored with proven (previously FDA-approved) technology as a "ground truth". These women will be simultaneously monitored with both an external and internal oxygen sensor. Obstetric health-care providers are blinded to oximetry data presented by both devices; therefore, clinical decisions regarding interventions are made based on the standard factors, including cardiotocography. The primary efficacy analysis will be performed retrospectively by comparing data of fetal oxygenation displayed and recorded by both devices. Results of either the Lumerah external sensor or the internal sensor will not be used to guide or alter patient management.

Conditions

Interventions

TypeNameDescription
DEVICEDual fetal oxygen sensorsPlacement of both internal and external fetal oxygen sensors

Timeline

Start date
2022-07-20
Primary completion
2023-11-29
Completion
2023-11-29
First posted
2021-12-07
Last updated
2025-02-04
Results posted
2025-02-04

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT05147584. Inclusion in this directory is not an endorsement.