Trials / Completed
CompletedNCT05108584
Intubation in Coronavirus Disease 19 With Level 3 PPE
The Intubation Procedure in COVID-19 Pandemic
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 39 (actual)
- Sponsor
- Indonesia University · Academic / Other
- Sex
- All
- Age
- 18 Years – 59 Years
- Healthy volunteers
- Not accepted
Summary
The World Health Organization (WHO) declared COVID-19 as a pandemic in April 2020. COVID-19 first discovered in Wuhan, China in December 2019. As of May 4th, 2020, the total number of patients in China was 82,880, the number of deaths was 4,633, the death rate was 3.7%. In Indonesia, until May 4th 2020, there were 11,192 confirmed cases of COVID-19 with a total of 845 deaths. High transmission and death due to the severe acute respiratory syndrome coronavirus 2, patients with respiratory failure symptoms were suspected of having COVID-19 until declared negative. A potential and continuing threatening complication is acute respiratory failure. Patient with Acute Respiratory Distress Syndrome (ARDS) require both respiratory support and oxygen therapy. The choosing of endotracheal intubation is generally indicated in moderate to severe ARDS. Apart from respiratory failure, endotracheal intubation is also commonly performed in patients undergoing surgical procedures under general anesthesia for the management of the patient's airway. To prevent transmission to medical personnel, intubation is carried out using PPE according to the guidelines. Guidance for intubation in COVID-19 patients is recommended to use a video laryngoscope because it offers several advantages such as assisting glottis visualization and making the intubation operator more distant from the patient's mouth when compared to direct laryngoscopes. This study aims to see the effect of using PPE and the type of laryngoscope on the intubation process carried out in the COVID-19 pandemic. This study is a preliminary study aimed at seeing the effect size of the recommended PPE use on the process and success of intubation.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | PPE Level 3 and Video Laryngoscope | The operator used level 3 PPE and video laryngoscope for the intubation process |
| PROCEDURE | PPE Level 3 and Direct Laryngoscope | The operator used level 3 PPE and direct laryngoscope for the intubation process |
| PROCEDURE | PPE Level 2 and Direct Laryngoscope | The operator used level 2 PPE and direct laryngoscope for the intubation process |
Timeline
- Start date
- 2021-11-19
- Primary completion
- 2022-01-04
- Completion
- 2022-02-10
- First posted
- 2021-11-05
- Last updated
- 2025-05-02
Locations
1 site across 1 country: Indonesia
Source: ClinicalTrials.gov record NCT05108584. Inclusion in this directory is not an endorsement.