A Model for Predicting Extubation Success in Premature Babies

A Model for Predicting Extubation Success Based on the "Extubation Readiness Estimator" and Lung Ultrasonography Score in Premature Babies

Status
Unknown
Phase
Study type
Observational
Enrollment
114 (estimated)
Sponsor
Marmara University · Academic / Other
Sex
All
Age
48 Hours – 60 Days
Healthy volunteers
Not accepted

Summary

Invasive mechanical ventilation is a life-saving treatment in critically ill newborns with respiratory failure. However, continuing this treatment for a long time may have negative consequences, especially bronchopulmonary dysplasia (BPD) secondary to mechanotrauma. For this reason, it is essential to terminate the mechanical ventilation treatment at the most appropriate time. About half of the extremely preterm babies may fail extubation even if the clinical criteria traditionally used for extubation are met. Unsuccessful extubation is associated with increased intraventricular bleeding, death, BPD, death or BPD, longer duration of ventilator support. When respiratory failure and lung pathologies of extremely preterm babies begin to improve, the target for mechanical ventilation should be early and successful extubation. Currently, the decision to extubate a preterm baby is primarily based on clinical judgment. Only a few studies that showed the low predictive value and limited utility using different measures have evaluated readiness for extubation. Lung ultrasonography (USG) is a noninvasive bedside technique that has been found useful for predicting the success of weaning from the ventilator in adults; however, very little data are available in neonates. In a recently published study, it was proposed an extubation readiness estimation tool based on clinical and demographic data of preterm babies who were attempted elective extubation. The researchers' hypothesis is that the use of a model based on extubation success scoring and lung USG scoring before extubation reduces the failure of the first extubation attempt in very low birth weight infants. The aim of the study is to evaluate the value of using an integrated model based on pre-extubation "extubation readiness predictor" and lung USG scoring to predict extubation success in preterm babies undergoing invasive mechanical ventilation.

Detailed description

Long-term invasive mechanical ventilation may have detrimental effects in preterm infants, although it is a life-saving treatment in critically ill newborns with respiratory failure. (e.g. bronchopulmonary dysplasia (BPD), superimposed bacterial infections and colonization, air leak, etc.). For this reason, it is essential to terminate the mechanical ventilation treatment at the most appropriate time. A significant portion of the extremely preterm babies may fail extubation even if the clinical criteria traditionally used for extubation are met. Unsuccessful extubation is associated with increased intraventricular bleeding, death, BPD, death or BPD, longer duration of ventilator support. When respiratory failure and lung pathologies of extremely preterm babies begin to improve, the target for mechanical ventilation should be early and successful extubation. Currently, the decision to extubate a preterm baby is primarily based on clinical judgment. Only a few studies that showed the low predictive value and limited utility using different measures have evaluated readiness for extubation. Lung ultrasonography (USG) is a noninvasive bedside technique that has been found useful for predicting the success of weaning from the ventilator in adults; however, very little data are available in neonates. In a recently published study, it was proposed an extubation readiness estimation tool based on clinical and demographic data of preterm babies who were attempted elective extubation. The researchers' hypothesis is that the use of a model based on extubation success scoring and lung USG scoring before extubation; reduces the failure of the first extubation attempt in very low birth weight infants. The aim of the study is to evaluate the value of using a model based on pre-extubation "extubation readiness predictor" and lung USG scoring to predict extubation success in preterm babies undergoing invasive mechanical ventilation. This study is a prospective observational study. The study is planned to be conducted in infants with a birth weight \<1250 g, who were intubated within the first 7 days of life, remained intubated invasive conventional mechanical ventilation for at least 48 hours, did not complete the postnatal 60 days, and met the traditional extubation criteria of the institution and were considered for elective extubation for the first time. An "informed consent form" will be obtained from the parents of the babies included in the study. The birth dates, protocol numbers, birth types, maternal histories, genders, weeks of gestation and birth weights of the babies will be recorded. The usual institutional routine approaches will be applied after the baby is born.

Conditions

Interventions

TypeNameDescription
OTHERA model for predicting extubation success based on extubation readiness estimator and lung ultrasonography scoreParameters to be recorded before and after extubation to create a "new dual extubation model" from all babies who met the extubation criteria included in the study: 1. "Lung ultrasound score": Lung ultrasound will be performed prior to the extubation and after the extubation. Lung aeration will be scored based on three chest areas for each side (upper anterior, lower anterior and lateral) and a score of 0 to 3 points will be given for each area (Total score ranges from 0 to 18 points). 2. "Probability of Successful Extubation": It will be calculated by extubation readiness estimator provided by the website named http://extubation.net/. This parameter will be calculated only 1 hour prior to the scheduled extubation time.

Timeline

Start date
2021-04-20
Primary completion
2023-04-20
Completion
2024-04-20
First posted
2021-10-18
Last updated
2021-10-18