Clinical Trials Directory

Trials / Completed

CompletedNCT05058066

10-year Follow-up of a Wide Diameter Bone Anchored Hearing Implant

Long-term Follow-up of a Wide Diameter Bone Anchored Hearing Implant: the 10-year Experience on Stability, Survival and Tolerability of the BIA300®

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
51 (actual)
Sponsor
Radboud University Medical Center · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

A single centre, open, comparative, parallel group, prospective clinical investigation with a single 10 year follow up visit.

Detailed description

This study is a continuation of two previous conducted trials: 1. Stability, long term survival and tolerability of a novel Baha® implant system, a multi-centre investigation new BIA300 (test) implant vs previous generation (control) implant: 1. CAG5173: 6-month(1) and 3-year(2) data. 2. CBAS5562: 5-year data(3). 2. 3 weeks loading: stability, long term survival and tolerability of a novel Baha® implant system, a multi-centre investigation 3 week loading vs 6+ week loading (= same group as control group trial 1). 6- month(4) and 3-year(5) data. In this study the (5-year data for trial 2 and) 10-year data regarding stability, survival and soft tissue tolerability from the above mentioned trials will be evaluated and compared. The previous trials were multicentre, but the current study will be single-centred and therefore only include the participants of the Radboud site. Data will be collected at a visit at (5 years, for trial 2 and) 10 years (+/- 6 months) after implantation. Up to now, no RCT of these implants (with the loading of 3 weeks after implantation) has assessed stability, survival and tolerability over a 10-year follow-up period.

Conditions

Interventions

TypeNameDescription
DEVICEBaha® flange fixture (diameter 3.75mm; length 4mm) with 6mm abutmentThe control implant included the previous generation as-machined titanium Baha® flange fixture (diameter 3.75mm; length 4mm) with 6mm conically shaped abutment.
DEVICEBaha® BIA300 Implant (diameter 4.5mm; length 4mm) with 6mm abutmentThe test implant and the implant used for the 3-week loading trial included the wide diameter titanium implant (diameter 4.5mm; length 4mm) with 6mm rounded, apically converging titanium abutment developed by Cochlear Bone Anchored Solutions AB (Mölnlyncke, Sweden). This system with an additional minor change to the internal abutment connection design was later commercialized under the name Cochlear™ Baha® BIA300 Implant with abutment. In addition to the difference in abutment shape and the wider diameter, the test implant incorporates small-sized threads at the implant neck and the moderately rough TiOblast™ (Dentsply, Mölndal, Sweden) surface on the intraosseous part of the implant6-8.
PROCEDUREEarly loadingLoading the implant at 3 weeks after implantation (instead of 6 weeks after implantation)

Timeline

Start date
2019-06-24
Primary completion
2020-09-21
Completion
2020-09-21
First posted
2021-09-27
Last updated
2025-11-18

Locations

1 site across 1 country: Netherlands

Source: ClinicalTrials.gov record NCT05058066. Inclusion in this directory is not an endorsement.