Trials / Unknown
UnknownNCT04991220
Evaluation of the Changes of Pleth Variability Index During Preoxygenation for Predicting Hypotension
Evaluation of the Changes of Pleth Variability Index During Preoxygenation for Predicting Hypotension During Induction of Anesthesia in Surgical Patients; Prospective Observational Study
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 96 (estimated)
- Sponsor
- Seoul National University Hospital · Academic / Other
- Sex
- All
- Age
- 19 Years
- Healthy volunteers
- Not accepted
Summary
The aim of this study is to investigate whether the change in pleth variation index (PVI) according to preoxygenation can predict hypotension during anesthesia induction.
Detailed description
In patients with hypovolemia or dehydration, pulse pressure variation can be increased by spontaneous forced inspiratory breathing. PVI is a noninvasive method of indicator of fluid responsiveness like purse pressure variation. We expected that the amount of change in PVI between at the time of entering operating room and after preoxygenation with forced inspiration method could be different depending on the patient's volume status. After entering operating room, monitoring devices, anesthesia depth sensor, and Radical-7® Pulse CO-Oximeter® are attached. Patients rest for 5 minutes, and then baseline systolic blood pressure, diastolic blood pressure, mean blood pressure, and heart rate are collected every 1-minute. Pleth variability index (PVI), perfusion index (PI) are also measured continuously. For pre-oxygenation of anesthesia, take 8 deep breaths at flow 10 l/min of 100% oxygen for 1 minute with maximally forced inspiration. After that, for 2 minutes, patients breathe as usual while maintaining oxygen supply. until tracheal intubation or laryngeal mask insertion. Anesthesia is induced with target concentration infusion of 4.0 ng/ml of remifentanil and 4.0 ug/ml of propofol. When the patient loses consciousness, rocuronium 1.0 mg/kg is administrated and endotracheal tube or laryngeal mask is inserted 2 minutes after. PVI, PI, blood pressure, and heart rate are measured until tracheal intubation or laryngeal mask insertion. Anesthesia induction-related hypotension is defined as a decrease in mean arterial pressure below 60 mmHg at any timepoint from baseline parameter collection to until airway device insertion. The parameters are analyzed by comparing between groups with and without anesthesia induction-related hypotension.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Preoxygenation | Taking 8 deep breaths at 10 l/min of 100% oxygen for 1 minute with forced inspiration for pre-oxygenation |
Timeline
- Start date
- 2021-08-30
- Primary completion
- 2022-08-01
- Completion
- 2022-12-01
- First posted
- 2021-08-05
- Last updated
- 2021-08-05
Locations
1 site across 1 country: South Korea
Source: ClinicalTrials.gov record NCT04991220. Inclusion in this directory is not an endorsement.